INSTALLATION DIAGRAMS
97
aisy chain installation for a video door entry system without distributor and d
D
.c lock release.
The installation diagram shows the connection of a video door entry system with one door
panel to access the building, and with a daisy chain installation without distributor and
d.c. lock release.
98
Sections chart
RAP-2150
Terminal
SECTIONS CHART
100m.
Door panel-Monitor
P.S. - Door panel
+, -
For greater distances contact our technical
support department.
BUS, D
REMEMBER:
.
The total number of daisy chain elements in the installation (monitors or
telephones) must never exceed 16 units
C
.
onfiguring the end of
line in the last monitor
*
50m.
Door panel - CV
50m.
2,5mm²
CV1,CV2
0,5mm²
BUS IN
PA PB
BUS OUT
HZ
Platea V2Plus
BUS IN
PA PB
BUS OUT
HZ
Platea V2Plus
Sw2
Sw2
*
SEC
PRI
+
0110230
FA-V2PLUS
- -
+
Main
Master door panel
CV1
+12
CV2
SW1
6
BUS
2
Core max. electrical resistence to 20ºC
ELECTRICAL CHARACTERISTICS
19,5 W/Km
Nominal capacitance (core-core)
Characteristic impedance
VALUES
CONSTRUCTIVE CHARACTERISTICS
Class V
VALUES
Flexible bare copper conductor of 1mm (twisted)
AP-2150 cable characteristics.
R
45pf/m 10%
100 W 10%
+
-
+
-