PRODUCT IDENTIFICATION
14
MODEL # MFG # DESCRIPTION
HANG11-12
P1210305F
P1210306F
High Altitude Natural Gas Kit
. For use with Goodman® and Amana® Brand 90% furnace
models
ACS9, AMS9, DCS9, DMS9, GCS9
and
GMS9.
These kits are required when installing
the furnaces above their maximum rated altitude. This kit contains natural gas orifices. The
orifices in the kit have been selected with the American Gas Association. They will provide
appropriate derating at the altitude listed in the High Altitude Charts as shown in the installations
of the kit.
HANG13-14
P1210307F
P1210308F
High Altitude Natural Gas Kit
. For use with Goodman® and Amana® Brand 90% furnace
models
AMV9, GMV9, GMV95.
These kits are required when installing the furnaces above their
maximum rated altitude. The orifices in the kit have been selected as a result of testing with the
American Gas Association. They will provide appropriate derating at the altitude listed in the
High Altitude Charts as shown in the installations of the kit.
HANG16
P1210310F
High Altitude Natural Gas Kit
. For use with Goodman® and Amana® Brand 90% furnace
models
ACV9, GCV9.
These kits are required when installing the furnaces above their
maximum rated altitude. The orifices in the kit have been selected as a result of testing with the
American Gas Association. They will provide appropriate derating at the altitude listed in the
High Altitude Charts as shown in the installations of the kit.
HAPS27-29
P1210518F
through
P1210520F
High Altitude Pressure Switch Kit
. For use with selected Goodman® and Amana® Brand 90%
furnace models
AMS9, ACS9, DCS9, DMS9, GSC9, GMS9, AMV9, GMV9 and GMV95.
This kit
contains a high altitude pressure switch that must be used at altitudes above the rated altitudes
because of reduced air density.
HAPS31
P1210522F
High Altitude Pressure Switch Kit
. For use with selected Goodman® and Amana® Brand 90%
furnace models
ACV9, GCV9.
This kit contains a high altitude pressure switch that must be
used at altitudes above the rated altitudes because of reduced air density.
LPLP01
P1237701F
LP Gas Low Pressure Kit. Designed for application on Goodman® and Amana® Brand's 90%
single-stage and two-stage gas fired furnace product installed on LP gas listed in this manual.
The kit monitors gas line pressure with a pressure switch and disables the unit's gas valve if the
line pressure drops below acceptable levels. Application of the LPLP kit is aimed at reducing the
occurrence of sooted heat exchangers in product installed on LP gas.
LPT-00A
N/A
LP Conversion Kit
. For use with Goodman®, Amana® Brand & Amana® Distinctions™ Brand
models
ADS8, AMS8, GDS8, GMS8, DMS8, DDS8, DHS8, GHS8, ACS9, AMS9, AMS95,
DCS9, DMS9, GCS9, GKS9, GMS9 and GMS95.
This kit converts
only
single-stage gas fired
units from natural to propane gas. The conversion from natural gas (as shipped from the factory)
to propane gas requires: replacing the burner orifices, replacing gas valve regulator spring (all
single stage units) and applying identification labels.
NOx screens must be removed when
converting 80% furnaces to this LP kit.
LPM-03B
N/A
LP Conversion Kit
. For use with Goodman® and Amana® Brand 80% and 90% 2-stage
variable speed models. This kit includes the LP gas valve, (1.25mm, # 55 orifices), installation
instructions and a label to show that the furnace has been converted.
LPM-05
N/A
LP Conversion Kit
. For use with Goodman® and Amana® Brand 2-stage variable speed
models using a White-Rodgers 36G54 2-stage gas valve kit. Includes regulator springs, #55
orifices, instructions and a label to show the furnace has been converted to L.P.
RF000180
N/A
Internal Filter Retention Kit.
For use with Goodman®, Amana® Brand & Amana®
Distinctions™ Brand 90%
upflow only
furnaces. This kit allows a filter to be installed in the
bottom of the furnace and contains enough hardware for (10) furnaces. This kit is NOT to be
used on horizontal applications.
RF000181
N/A
Internal Filter Retention Kit.
For use with Goodman®, Amana® Brand and Amana®
Distinctions™ Brand 90%
counterflow only
furnaces. This kit allows a filter to be installed in the
bottom of the furnace and contains enough hardware for (10) furnaces. This kit is NOT to be
used on horizontal applications.
SBT14
SBT17
SBT21
SBT24
N/A
Downflow Subbase.
For use with Goodman® and Amana® Brand 80% dedicated downflow
furnace models
ADV8, ADS8, GDS8 and GDH8
. These kits are available for the following
furnace widths: 14" wide (SBT14) 17.5" wide (SBT17), 21" wide (SBT21) and 24" wide (SBT24).