50
COOLING PERFORMANCE DATA
GSX130181E*
MODEL: GSX130181E* + CAPF1824B6DB
EXPANDED PERFORMANCE DAT
A
COOLING OPERATION
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67715963677159636771
MBh 15.6 16.2 17.7 - 15.3 15.8 17.3 - 14.9 15.4 16.9 - 14.5 15.1 16.5 - 13.8 14.3 15.7 - 12.8 13.3 14.5 -
S/T 0.70 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.62 0.43 - 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.81 0.67 0.47 -
Delta T 19 17 13 - 19 17 13 - 20 17 13 - 20 17 13 - 19 17 13 - 18 16 12 -
525 KW 1.02 1.04 1.08 - 1.11 1.13 1.17 - 1.18 1.21 1.25 - 1.25 1.28 1.32 - 1.30 1.33 1.38 - 1.35 1.38 1.43 -
AMPS 4.3 4.4 4.5 - 4.6 4.7 4.9 - 5.0 5.1 5.3 - 5.4 5.5 5.7 - 5.7 5.8 6.0 - 6.0 6.2 6.4 -
HI PR 203 219 231 - 228 245 259 - 259 279 294 - 295 318 335 - 332 357 377 - 367 395 417 -
LO PR 102 109 119 - 108 115 126 - 113 120 131 - 118 126 137 - 124 132 144 - 128 136 149 -
MBh 16.4 17.0 18.7 - 16.0 16.6 18.2 - 15.7 16.2 17.8 - 15.3 15.8 17.4 - 14.5 15.0 16.5 - 13.4 13.9 15.3 -
S/T 0.71 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.69 0.47 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
70 600 KW 1.03 1.06 1.09 - 1.12 1.14 1.18 - 1.19 1.22 1.27 - 1.26 1.29 1.34 - 1.32 1.35 1.40 - 1.37 1.40 1.45 -
AMPS 4.3 4.4 4.6 - 4.7 4.8 4.9 - 5.1 5.2 5.4 - 5.4 5.6 5.7 - 5.8 5.9 6.1 - 6.1 6.3 6.5 -
HI PR 206 221 234 - 231 248 262 - 263 283 298 - 299 322 340 - 336 362 382 - 372 400 422 -
LO PR 104 110 121 - 110 117 127 - 114 121 132 - 120 127 139 - 126 134 146 - 130 138 151 -
MBh 16.9 17.6 19.2 - 16.5 17.1 18.8 - 16.1 16.7 18.3 - 15.8 16.3 17.9 - 15.0 15.5 17.0 - 13.9 14.4 15.7 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.84 0.70 0.48 -
Delta T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
650 KW 1.05 1.07 1.11 - 1.14 1.16 1.20 - 1.21 1.24 1.29 - 1.28 1.31 1.36 - 1.34 1.37 1.42 - 1.39 1.42 1.47 -
AMPS 4.4 4.5 4.6 - 4.7 4.9 5.0 - 5.2 5.3 5.5 - 5.5 5.6 5.8 - 5.9 6.0 6.2 - 6.2 6.4 6.6 -
HI PR 209 225 238 - 235 253 267 - 267 287 304 - 304 327 346 - 342 368 389 - 378 407 430 -
LO PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 142 - 128 136 148 - 132 141 153 -
MBh 15.916.417.719.015.516.017.318.615.215.616.918.114.8
15.2
16.5 17.7 14.0 14.5 15.7 16.8 13.0 13.4 14.5 15.6
S/T 0.800.720.540.350.830.740.560.360.850.760.580.370.88
0.78
0.59 0.38 0.91 0.81 0.62 0.40 0.92 0.82 0.62 0.40
Delta T22201712232117122321171223
21
17 12 22 21 17 12 21 19 16 11
525 KW 1.031.051.091.131.121.141.181.221.191.221.261.311.26
1.29
1.33 1.38 1.32 1.35 1.39 1.44 1.36 1.40 1.45 1.50
AMPS 4.3 4.4 4.6 4.7 4.7 4.8 4.9 5.1 5.1 5.2 5.4 5.6 5.4
5.5
5.75.95.85.96.16.36.16.36.56.7
HI PR205221233243230248262273262282297310298
321
339353335361381398371399421439
LO PR104110120128109116127135114121132141119
127
139148125133145155129138150160
MBh 16.717.218.620.016.316.818.219.515.916.417.819.115.5
16.0
17.3 18.6 14.8 15.2 16.5 17.7 13.7 14.1 15.2 16.4
S/T 0.810.730.550.350.840.750.570.370.860.770.580.380.89
0.80
0.60 0.39 0.92 0.83 0.63 0.40 0.93 0.83 0.63 0.41
Delta T21191611211916112119161121
20
16 11 21 19 16 11 20 18 15 10
75 600 KW 1.041.071.101.141.131.161.201.241.211.231.281.321.27
1.30
1.35 1.40 1.33 1.36 1.41 1.46 1.38 1.41 1.46 1.52
AMPS 4.4 4.5 4.6 4.8 4.7 4.8 5.0 5.2 5.1 5.2 5.4 5.6 5.5
5.6
5.86.05.86.06.26.46.26.36.56.8
HI PR208224236246233251265276265285301314302
325
343358340366386403376404427445
LO PR105112122130111118129137115123134142121
129
141150127135147157131140152162
MBh 17.217.719.220.616.817.318.720.116.416.918.319.616.0
16.5
17.9 19.2 15.2 15.7 17.0 18.2 14.1 14.5 15.7 16.9
S/T 0.830.740.560.360.860.770.580.370.880.790.600.380.91
0.81
0.62 0.40 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
Delta T20191511201915112019151121
19
16 11 20 19 15 11 19 17 14 10
650 KW 1.061.081.121.161.151.171.211.261.221.251.301.341.29
1.32
1.37 1.42 1.35 1.38 1.43 1.48 1.40 1.44 1.49 1.54
AMPS 4.4 4.5 4.7 4.9 4.8 4.9 5.1 5.3 5.2 5.3 5.5 5.7 5.6
5.7
5.96.15.96.16.36.56.36.46.66.9
HI PR211228240251237255270281270290307320307
331
349364346372393410382411434453
LO PR107114124132113120131139117125136145123
131
143152129137150160133142155165
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves. KW=Total system power