Page #1 background image
RECOGNIZE THIS SYMBOL
AS A SAFETY PRECAUTION.
ATTENTION INSTALLING PERSONNEL
Prior to installation, thoroughly familiarize yourself with this Installation Manual.
Observe all safety warnings. During installation or repair, caution is to be observed.
It is your responsibility to install the product safely and to educate the customer on its safe use.
ARUF**14**/ARPT**14**
1 Important Safety Instructions
The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards. It
is the owner’s and installer’s responsibility to read and com-
ply with all safety information and instructions accompanying
these symbols. Failure to heed safety information increases
the risk of personal injury, property damage, and/or product
damage.
ASPT**14**/ASUF**14**
AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS
1 Important Safety Instructions ..................................................1
2 Shipping Inspection ................................................................2
2.1 Parts ..............................................................................2
2.2 Handling ........................................................................3
3 Codes & Regulations..............................................................3
4 Replacement Parts .................................................................3
5 Pre-Installation Considerations..............................................3
5.1 Preparation....................................................................3
5.2 System Matches............................................................3
5.3 Interconnecting Tubing ..................................................3
5.4 Clearances ....................................................................3
5.5 Horizontal Applications ..................................................3
6 Installation Location...............................................................3
6.1 Upflow Installation .........................................................4
6.2 Horizontal Left Installation .............................................4
6.3 Downflow/Horizontal Right Installation ..........................4
7 Refrigerant Lines ....................................................................6
7.1 Tubing Size ...................................................................6
7.2 Tubing Preparation ........................................................6
7.3 Special Instructions .......................................................6
7.4 Tubing Connections for Flowrator Model ......................7
7.5 Tubing Connections for TXV Models.............................7
8 Condensate Drain Lines .........................................................7
9 Ductwork.................................................................................8
9.1 Return Ductwork ...........................................................8
10 Return Air Filters...................................................................8
11 Electric Heat .........................................................................8
11.1 No Electric Heat Installed ............................................9
12 Electrical and Control Wiring ..............................................10
12.1 Building Electrical Service Inspection .......................10
12.2 Wire Sizing ...............................................................10
12.3 Maximum Overcurrent Protection (MOP) ..................10
12.4 Electrical Connections – Supply Voltage .................. 11
12.4.1 Air Handler Only (Non-Heat Kit Models) ........ 11
12.4.2 Air Handler - Non-Circuit Breaker Heat Kits .......... 11
12.4.3 Air Handler With Circuit Breaker Heat Kit ............. 11
12.5 Low Voltage Connections ......................................... 11
12.5.1 Thermostats ......................................................... 11
12.6 Speed Tap Adjustment .............................................. 11
13 Achieving 2% Low Leakage Rate .......................................12
14 Start-Up Procedure.............................................................12
15 Regular Maintenance .........................................................12
Airflow Data ................................................................................13
Schematics ................................................................................15
Wiring Diagrams ........................................................................21
IO-427G
10/2013

Other manuals for Goodman RS6200006

Question and Answer IconNeed help?

Do you have a question about the Goodman RS6200006 and is the answer not in the manual?

Goodman RS6200006 Specifications

General IconGeneral
ModelRS6200006
Airflow2000 CFM
RefrigerantR-410A
Phase1
Cooling Capacity5 Ton
Heating Capacity60, 000 BTU/h
Voltage208/230V
Nominal Cooling Capacity5 Ton
Nominal Heating Capacity60, 000 BTU/h

Summary

Important Safety Instructions

Safety Symbols and General Precautions

Explains safety symbols and general precautions for installation and operation.

Safety Warnings and Unit Handling

Electrical Safety Warnings

High voltage, grounding, and approved device warnings to prevent shock and damage.

Installation and Operation Safety

Warnings on technician qualifications, power supply, flammable materials, and CO hazards.

Shipping and Handling Guidelines

Instructions for inspecting the unit, verifying parts, and safe transport methods.

Pre-Installation Considerations

Codes, Regulations, and Parts

Compliance with codes, EPA regulations, and sourcing of replacement parts.

System Matching and Clearances

AHRI listing, system matches, refrigerant tubing, and clearance requirements.

Installation Location and Orientation

Indoor installation, orientation options, and specific considerations for horizontal applications.

Installation Orientations and Kits

Upflow and Horizontal Left Installation

Details drip shield removal and drain connections for upflow and horizontal left configurations.

Downflow/Horizontal Right Conversion

Explains the need for a downflow kit (DFK) and the conversion process for these orientations.

Refrigerant Line Installation Procedures

Refrigerant Line Safety and Preparation

Warnings on pressure, handling, brazing, tubing size, and preparation for safe installation.

Flowrator and TXV Special Instructions

Specific instructions for flowrator piston adjustment and general notes for TXV models.

Refrigerant Line Connections

Flowrator Model Tubing Connections

Step-by-step guide for connecting refrigerant lines on flowrator models, including purging and brazing.

TXV Model Tubing Connections

Step-by-step guide for connecting refrigerant lines on TXV models, including pressure release and brazing.

Condensate Drain Line Requirements

Details on primary/secondary drain connections, fittings, torque, and insertion depth.

Drainage, Ductwork, and Filters

Condensate Drainage System

Covers secondary drains, traps, pump usage, and insulation for condensate lines.

Ductwork Installation Guidelines

Information on duct sizing, materials, and proper connection to the air handler.

Return Air Filter Installation

Requirement for a return air filter, placement options, and filter types.

Electric Heat and Airflow Data

Electric Heat Kit Temperature Rise

How airflow, voltage, and heat kit size determine temperature rise for heating mode.

Airflow Estimation and Data Tables

Formula for estimating airflow and tables providing CFM data for various models.

No Electric Heat Configuration

Requirement for a cover plate when no electric heat kit is installed.

Electrical and Control Wiring

Service Inspection and Voltage

Inspection of building electrical service and verification of supply voltage agreement with unit requirements.

Wire Sizing and Protection

Guidelines for selecting wire size, using copper conductors, and installing maximum overcurrent protection.

Electrical Connections and Speed Adjustment

Supply Voltage and Heat Kit Wiring

Connecting supply voltage and heat kit power, including specific instructions for different heat kit types.

Low Voltage and Thermostat Wiring

Connecting low voltage wiring for thermostats and condensers, including wire gauge and routing.

Blower Speed Tap Adjustment

Instructions for changing blower motor speed by reconfiguring wire connections.

Start-Up Procedure and Maintenance

Low Airflow Leakage Requirements

Steps to achieve less than 2% airflow leakage by ensuring gasket and panel integrity.

Pre-Start-Up Checklist

Comprehensive checklist for wiring, panels, tubing, drainage, and protection before unit start-up.

Regular User Maintenance

User's responsibility for filter maintenance; other services require a technician.

Airflow Data for ARUF/ARPT Models

ARUF/ARPT Airflow Performance

Tables providing airflow data (CFM) for ARUF/ARPT models across various static pressures and blower speeds.

Airflow Data for ASPT/ASUF Models

ASPT Airflow Performance

Tables providing airflow data (CFM) for ASPT models across various static pressures and blower speeds.

ASUF Airflow Performance

Tables providing airflow data (CFM) for ASUF models across various static pressures and blower speeds.

Low Voltage Wiring Diagrams

Cooling Unit Wiring Diagrams

Diagrams for cooling units with optional heat kits, showing thermostat and contactor connections.

Heat Pump Wiring Diagrams

Diagrams for heat pump units with optional heat kits, showing thermostat and outdoor thermostat connections.

Heat Pump Wiring Diagrams

ARUF/ARPT Heat Pump Wiring

Wiring diagrams for ARUF/ARPT heat pumps with optional heat kits, including outdoor thermostat options.

ASPT/ASUF Thermostat and Wiring

ASPT/ASUF Cooling Unit Wiring

Wiring for ASPT/ASUF cooling units with heat kits, detailing thermostat and contactor connections.

ASPT/ASUF Heat Pump Unit Wiring

Wiring for ASPT/ASUF heat pumps with heat kits, detailing thermostat and outdoor thermostat connections.

ASPT/ASUF Unit Wiring Configurations

Cooling Unit with High Capacity Heat Kits

Wiring for ASPT/ASUF cooling units with 15kW+ heat kits, including outdoor thermostat options.

Heat Pump Unit with Low Capacity Heat Kits

Wiring for ASPT/ASUF heat pumps with 10kW and below heat kits, showing thermostat and outdoor thermostat connections.

ASPT/ASUF Heat Pump Wiring Details

Heat Pump Unit with High Capacity Heat Kits

Detailed wiring for ASPT/ASUF heat pumps with 15kW+ heat kits, including outdoor thermostat options.

Electronic Blower Time Delay Relay

Blower Delay Relay Operation and Timing

Diagram and explanation of the electronic blower time delay relay's function, timing, and field test mode.

ARUF/ARPT Wiring Diagrams

Heat Kit Wiring Schematics

Wiring schematics for ARUF/ARPT models with various heat kit configurations, including element rows.

Wiring Diagram Components and Codes

Explanation of component codes, wiring codes, and important notes for ARUF/ARPT wiring.

ASPT/ASUF Wiring Diagrams

Heat Kit Wiring Schematics

Wiring schematics for ASPT/ASUF models with various heat kit configurations, including element rows.

Wiring Diagram Components and Codes

Explanation of component codes, wiring codes, and important notes for ASPT/ASUF wiring.

Heat Kit Installation Wiring

3-Phase Heat Kit Wiring Diagram

Wiring diagram and notes for installing a 3-phase heat kit, including speed tap and label placement.

25kW Heat Kit Wiring Diagram

Wiring diagram and notes for installing a 25kW heat kit, including component and color codes.

Split Systems Routine Maintenance

Indoor Air Filter Maintenance

Guidance on checking, cleaning, or replacing indoor air filters to maintain system efficiency and prevent damage.

Compressor and Motor Lubrication

Information that compressor and fan motors are sealed and permanently lubricated.

Outdoor Coil Cleaning and Servicing

Recommendation for professional cleaning of the outdoor coil to ensure proper airflow and prevent damage.

Troubleshooting Before Service Call

Steps homeowners can take to check before calling a qualified servicer, such as thermostat settings and electrical panel.