EasyManua.ls Logo

Goodwe GW50KN-MT - User Manual

Goodwe GW50KN-MT
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MT G2 SERIES USER MANUAL
SOLAR INVERTER
SEMS Portal App
LinkedIn
SolarGo App
Offical Website
Ver 2.0
2021-08-20
GOODWE (Germany)
Fürstenrieder Str. 279a 81377 München, Germany
sales.de@goodwe.com
service.de@goodwe.com
GOODWE (Brazil)
Rua Abelardo 45, Recife/PE, 52050-310
sergio@goodwe.com
servico.br@goodwe.com
GOODWE (Netherlands)
Franciscusdreef 42C, 3565AC Utrecht, the Netherlands
sales@goodwe.com
service.nl@goodwe.com
GOODWE (UK)
6 Dunhams Court, Dunhams Lane, Letchworth
Garden City, SG6 1WB UK
enquiries@goodwe.com.uk / service@goodwe.com.uk
GOODWE (India)
1202, G-Square Business Park, Sector 30A, Opp. Sanpada
Railway Stn., Vashi, Navi Mumbai- 400703
sales@goodwe.com / service.in@goodwe.com
GOODWE (Italy)
Via Cesare Braico 61, 72100 Brindisi, Italy
valter.pische@goodwe.com (sales)
operazioni@topsenergy.com; goodwe@arsimp.it (service)
GOODWE (Turbutton)
Adalet Mah. Megapol Tower K: 9 No: 110 Bayraklı - Izmir
info@goodwe.com.tr
service@goodwe.com.tr
GOODWE (Australia)
Level 14, 380 St. Kilda Road, Melbourne,
Victoria, 3004, Australia
sales@goodwe.com / service.au@goodwe.com
GOODWE (Mexico)
Oswaldo Sanchez Norte 3615, Col. Hidalgo, Monterrey,
Nuevo Leon, Mexico, C.P. 64290
sales@goodwe.com / soporte.latam@goodwe.com
GOODWE (Korea)
8F Invest Korea Plaza, 7 Heoleung-ro
Seocho-gu Seoul Korea (06792)
sales@goodwe.com / Larry.Kim@goodwe.com
GOODWE (China)
No. 90 Zijin Rd., New District, Suzhou, 215011, China
T: 400-998-1212
sales@goodwe.com (sales)
service@goodwe.com (service)
Note: The information above is subject to change without prior notice, for details refer to
www.goodwe.com
340-00566-01

Questions and Answers

  • D
    dmoralesAug 17, 2025
    How to fix Goodwe Inverter Wi-Fi module if it fails to connect to the network?
    • B
      breweralyssaAug 17, 2025
      If the Wi-Fi module fails to connect to the network after entering the correct router hotspot and password, the password might contain special characters not supported by the module. Change the password to include only Arabic numerals or uppercase/lowercase letters.
  • M
    Michele RiveraAug 23, 2025
    What to do if my Goodwe GW50KN-MT Inverter has Relay-Check Failure?
    • A
      Adam BaileyAug 23, 2025
      If your Goodwe Inverter shows a Relay-Check Failure: 1. Turn off the DC switch of the inverter. 2. Wait until the inverter's LCD light is off. 3. Turn on the DC switch and ensure it is connected.
  • A
    Adam WilliamsAug 26, 2025
    What to do if my Goodwe GW50KN-MT shows 'Utility Loss'?
    • E
      Elizabeth MartinezAug 26, 2025
      If your Goodwe Inverter displays a 'Utility Loss' error, it means it's not connected to the power grid. First, check if the power grid cable is properly connected. Also, verify the availability of the power grid itself.
  • S
    swilliamsAug 28, 2025
    Why is my Goodwe GW50KN-MT Inverter showing a 'Vac Failure'?
    • M
      Mr. Randall SavageAug 28, 2025
      A 'Vac Failure' on your Goodwe Inverter indicates a grid voltage issue. The inverter should automatically restart within 5 minutes if the grid returns to normal. Ensure the grid voltage conforms to the specified requirements and that the neutral (N) and protective earth (PE) wires are securely connected.
  • W
    williamsnatashaAug 30, 2025
    How to fix a 'Fac Failure' on a Goodwe GW50KN-MT Inverter?
    • B
      Brian MooreAug 31, 2025
      If your Goodwe Inverter is showing 'Fac Failure', this means the grid is not connected. Check the grid connection cables and verify the availability of the grid.
  • G
    Gina AndersonSep 2, 2025
    What to do if my Goodwe Inverter is overheating?
    • K
      Kathleen RuizSep 2, 2025
      If your Goodwe Inverter is experiencing an 'Over Temperature' error, it means the internal temperature is higher than the specified normal value. Try to reduce the ambient temperature or move the inverter to a cooler location.
  • J
    Jeffrey FarmerSep 5, 2025
    What does 'Ground I Failure' mean on my Goodwe GW50KN-MT?
    • K
      Kimberly JacobsSep 5, 2025
      If your Goodwe Inverter displays 'Ground I Failure', it indicates that the ground current is too high. Disconnect the inputs from the PV generator and inspect the peripheral AC system. Once the problem is resolved, reconnect the PV panel and check the Inverter status.
  • L
    Linda RodriguezSep 8, 2025
    Why is my Goodwe GW50KN-MT showing 'PV Over Voltage'?
    • J
      James MartinezSep 8, 2025
      If your Goodwe Inverter is showing 'PV Over Voltage', verify that the PV open circuit voltage is not higher or too close to the maximum input voltage.
  • D
    Dawn MathisSep 12, 2025
    How to troubleshoot a 'Relay-Check Failure' on a Goodwe GW50KN-MT Inverter?
    • D
      David GonzalesSep 12, 2025
      If your Goodwe Inverter displays 'Relay-Check Failure', turn off the DC switch of the inverter and wait until the LCD light turns off. Then, turn the DC switch back on, ensuring it is properly connected.
  • M
    Michael DavidSep 13, 2025
    What does 'Isolation Failure' mean on my Goodwe GW50KN-MT?
    • C
      Cynthia MarshallSep 13, 2025
      If your Goodwe Inverter displays 'Isolation Failure', check the impedance between Ground and PV (+) & PV (-). The impedance value must be greater than 100k?. Also, ensure the inverter is properly earthed.

Summary

2 Safety Measures & Warning

3 Product Introduction

3.3 Technical Description

4 Installation

4.3 Electrical Connection

4.3.1 AC Grid Connection

Details how to connect the inverter to the AC grid, including breaker specifications and wiring methods.

4.3.2 AC Circuit Breaker & RCD

Recommends circuit breaker ratings and explains the need for residual current protection.

4.3.3 Earth Terminal Connection

4.3.4 PV Panel Connection

4.4 Communication Connection

4.3.5 DC Switch

4.4.3 Wi-Fi Communication

4.4.4 Earth Fault Alarm

4.4.7 SEMS Portal

5 System Operation

5.1 LCD Panel & LED Indicators

Describes the inverter's LCD panel and LED indicators for system status and operation.

5.2 User Interface Introduction

5.3.1 Menu Architecture Overview

5.3 System Configuration

5.4.1 Basic Settings

Covers essential settings like language, time, communication, and safety configurations.

5.4.3 History Information

5.4.4 Startup Display Operation

5.4.5 Menu Introduction

5.4 Wi-Fi Reset & Reload

5.5 Initial Startup Precautions

5.6 Error Messages

6 Troubleshooting

5.7 Special Adjustable Setpoints

7 Technical Parameters & Block Diagram

7.1 Technical Parameters

Presents detailed technical specifications for various MT series inverter models.

7.2 Block Diagram

8 Caution

Goodwe GW50KN-MT Specifications

General IconGeneral
ModelGW50KN-MT
Rated Output Power50000W
Start Voltage250 V
Number of MPPT4
MPPT Voltage Range200-850V
MPPT Efficiency99.9%
Efficiency98.6%
Max. Efficiency98.8%
Euro Efficiency98.3%
Max. AC Apparent Power55000VA
Rated Output Voltage400 V
AC Voltage Range310-480V
Frequency50/60Hz
THDi<3%
DC ConnectionMC4
Protection DegreeIP65
Cooling MethodSmart Fan Cooling
Weight70 kg
Protection LevelIP65
Max Input Voltage1100V
Output Voltage400 V
Power Factor0.8 leading to 0.8 lagging
AC ConnectionOT terminal
Operating Temperature Range-25°C to 60°C
Humidity0-100%
Input Voltage Range200-1000V