Goodwe GW5K-ET - User Manual

Goodwe GW5K-ET
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Manual
V1.1-2022-12-20
Hybrid Inverter
ET Series / ET Plus Series
5.0-10.0kW
AC-Coupled Inverter
BT Series
5.0-10.0kW

Other manuals for Goodwe GW5K-ET

Questions and Answers

  • R
    Roberto BarrSep 15, 2025
    What to do if Goodwe Inverter shows PV Continuous Hardware Overcurrent?
    • K
      kathywellsSep 16, 2025
      To address a 'PV Continuous Hardware Overcurrent' error on your Goodwe Inverter, disconnect the AC output switch and DC input switch, then reconnect them after 5 minutes. If the problem persists, contact the dealer or after-sales service.
  • E
    Elizabeth CharlesAug 25, 2025
    What to do if Smart Meter & CT connections are not working on Goodwe Measuring Instruments?
    • C
      Christopher ClarkeAug 25, 2025
      To resolve issues with Smart Meter & CT connections in your Goodwe Measuring Instruments, ensure that the Smart Meter and CT are properly connected between the house loads and the grid. Also, make sure to follow the Smart Meter direction sign on the CT.
  • D
    Dustin BrownAug 25, 2025
    How to troubleshoot on-grid and backup connections in Goodwe Measuring Instruments?
    • D
      David MurphyAug 26, 2025
      To resolve on-grid and backup connection problems with Goodwe Measuring Instruments, verify that the on-grid is connected to the power grid and the backup is connected to the loads. Also, check that the polarities (e.g. L1/L2/L3/N) are correctly aligned.
  • C
    Carlos CollinsAug 26, 2025
    Why is my Goodwe Inverter showing a utility loss?
    • M
      Melvin SnyderAug 27, 2025
      If your Goodwe Inverter is showing a utility loss, it could be due to a failure in the utility grid power or because the AC cable is disconnected, or the AC circuit breaker is off. Once the grid power supply is restored, the alarm should automatically clear. Ensure the AC cable is securely connected and the AC circuit breaker is turned on.
  • C
    choisandraSep 16, 2025
    What to do if Goodwe Inverter shows PV Continuous Software Overcurrent?
    • M
      Maurice RiceSep 17, 2025
      To address a 'PV Continuous Software Overcurrent' error on your Goodwe Inverter, disconnect the AC output switch and DC input switch, then reconnect them after 5 minutes. If the problem persists, contact the dealer or after-sales service.
  • U
    ureeseSep 23, 2025
    How to check battery connections on Goodwe Measuring Instruments?
    • L
      Logan WebsterSep 23, 2025
      To solve battery connection issues in Goodwe Measuring Instruments, confirm that the connections between the ET and the battery are properly established.
  • A
    Andrew HudsonSep 8, 2025
    Why is my Goodwe Inverter showing a Cavity Overtemperature error?
    • M
      Maria BrooksSep 8, 2025
      A 'Cavity Overtemperature' error on your Goodwe Inverter can be due to several reasons: 1. The inverter is installed in a location with poor ventilation. 2. The ambient temperature exceeds 60°C. 3. There is a fault with the internal fan of the inverter. To address this, first, check the ventilation and ambient temperature at the installation point. If ventilation is poor or the temperature is too high, improve ventilation and heat dissipation. If both are normal, contact the dealer or after-sales service.
  • V
    Victoria NavarroSep 9, 2025
    What does Anti-islanding mean on Goodwe GW5K-ET?
    • M
      melissa33Sep 9, 2025
      An 'Anti-islanding' error on your Goodwe Inverter indicates that the utility grid is disconnected, but the grid voltage is maintained due to the loads, according to safety regulations. Check whether the utility grid is disconnected and contact the dealer or after-sales service.
  • A
    angela40Sep 2, 2025
    How do I fix a PV Input Overvoltage error on my Goodwe GW5K-ET?
    • D
      david69Sep 2, 2025
      A 'PV Input Overvoltage' error on your Goodwe Inverter means that too many PV panels are connected in series in the PV string. Check the serial connection of the PV array, ensuring that the open circuit voltage of the PV string does not exceed the inverter's maximum operating voltage.
  • J
    Jack LinAug 31, 2025
    What causes an Abnormal GFCI 30mA error on a Goodwe GW5K-ET Inverter?
    • H
      harrisonmargaretSep 1, 2025
      An 'Abnormal GFCI 30mA' error on your Goodwe Inverter indicates that the input insulation impedance has become low during operation. If this occurs occasionally, it might be due to a cable issue, and the inverter should recover automatically once the problem is resolved. However, if the problem occurs frequently or persists, check whether the impedance between the PV string and PE is too low.

Summary

Safety Precaution

General Safety

Provides overarching safety guidelines for handling the equipment.

Inverter Safety

Covers critical safety instructions specific to inverter operation.

Battery Safety

Details safety precautions related to battery use and connection.

Installation

Installation Requirements

Specifies environmental and site conditions for installation.

Electrical Connection

Safety Precaution

Crucial safety measures before and during electrical connections.

Equipment Commissioning

System Commissioning

Setting Inverter Parameters via SolarGo App

Guide to configuring inverter settings using the mobile app.

Maintenance

Power OFF the Inverter

Procedure for safely shutting down the inverter.

Troubleshooting

Provides solutions for common faults and issues.

Technical Parameters

Technical Parameters - ET;ET Plus Series

Detailed technical specifications for ET/ET Plus models.

Technical Parameter - BT Series

Detailed technical specifications for BT models.

Goodwe GW5K-ET Specifications

General IconGeneral
BrandGoodwe
ModelGW5K-ET
CategoryInverter
LanguageEnglish