EasyManua.ls Logo

Gossen MetraWatt INTRO - Page 2

Gossen MetraWatt INTRO
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 GMC-I Messtechnik GmbH
Features Overview of Both Instrument Variants Scope of delivery:
1 Insulation and resistance measuring instrument
1 DAkkS calibration certificate (not METRISO INTRO)
1 Set batteries (8 ea. in battery holder) (not METRISO INTRO)
1Carrying strap
1 Alligator clip (not METRISO INTRO)
1 KS17-4 cable set
1 Condensed operating instructions
1 Supplement Safety Information
1 Detailed operating instructions for download from our website
at www.gossenmetrawatt.com
Battery Compartment Lid and Location of the Fuses
(housing bottom)
METRISO INTRO BASE TECH
Article number M550N M550O M550P
Measurements
R
INS
U = 1000 V
R
INS
U = 250, 500 V ✓✓✓
R
INS
U = 50, 100 V ✓✓
R 10 Ω ... 10 kΩ
✓✓
RLO 0.17 Ω ... 10 Ω
✓✓
U 0 ... 1000 V
U 0 ... 500 V
✓✓
Display Functions
Backlit display
✓✓
Limit value LED (green/red) for:
Additional acoustic signal, limit value per VDE 0100
R
INS
R
LO
R
INS
R
LO
R
INS
R
LO
LED for dangerous contact voltage
(when switched off)
✓✓
LCD symbol for external voltage
✓✓
Battery level display
✓✓
Special Functions
Discharge capacitive devices under test
✓✓
Safety shutdown (UBatt < 8 V)
✓✓
Features
CAT II 1000 V / CAT III 600 V / CAT IV 300 V
Measuring category CAT III 600 V / CAT IV 300 V
✓✓
10 MΩ test resistor
✓✓
DAkkS calibration certificate
✓✓
a b
Replacement Fuse
Fuse
Battery Compartment Lid

Table of Contents