6.3 Required additional parts
Because of the wide variety of installation possibilities the refrigeration unit is not
shipped with all parts needed for every possible installation situation. The installer
needs to make sure that the following parts are readily available.
We recommend keeping the following additional parts ready in a box before starting
the installation process:
4 threaded bolts
of appropriate length and strength. The appropriate length de-
pends on the thickness of the wall onto which you mount the re-
frigeration unit. The bolts must be strong enough to carry the dy-
namic weight of the unit. If you are not sure that the strength of the
bolts is sufficient, consult professional help.
8 Washers (8)
of suitable size depending on the trailer‘s structure
8 self locking nuts
1 lamp (110 V AC, max 60 W)
to attach inside the trailer box; the refrigeration unit is equipped
with electrical wiring to connect such a lamp. Find the wiring rolled
up in the intake opening of the evaporator.
1 evaporator drain pipe or drain hose
(with an internal diameter of 19/32") of suitable length
1 electrical wiring
of suitable length with standard 3-prong grounded socket on one