SPECIFICATIONS
Gallon Models Litre Models
Model
Designation
QM240N or QM40-G8N QM150N or QM40-L8N
Unit of Measure
US Gallon Litre
Flow Range 2 to 40 GPM 8 to 150 LPM
Typical Accuracy
(Factory Set)
1
Diesel: ±05% (15-30 GPM/57-113 LPM)
±10% all other flowrates
Unleaded: +05% to -15% (15-30 GPM/57-113 LPM)
±20% all other flowrates
Typical Accuracy
(Field/Customer
Set)
1
Diesel: ±025% at a given flow (15-30 GPM/57-113 LPM)
±05% all other given flows
Unleaded: ±05% at a given flow (2-23 GPM/8-87 LPM)
±05% at a given flow (23-40 GPM/87-150 LPM)
2
Resolutional
Error (Display)
(001/Dispensed
Amount)*100
(01/Dispensed
Amount)*100
Operating
Temperature
-20°F to 125°F -29°C to 52°C
Maximum Work-
ing Pressure
50 PSIG / 34 Bar
Wetted Materials:
Housing / Cover
/ Fittings
Aluminum
Rotors PPS (Polyphenylene Sulde)
Shafts / Strainer Stainless Steel
Seals NBR (Nitrile Butadiene Rubber)
Mag-Drive Acetal, Stainless Steel and Neodymium (Nickel Plated)
Inlet/Outlet Ports 1" NPT (female) 1" NPT (female)
Pressure Drop
(at Max Flow)
Diesel: 70 PSI / 05 Bar
Unleaded: 45 PSI / 03 Bar
Maximum
Batch Total
9999 9999
Maximum
Cumulative Total
9,999,9999 99,999,999
Technology Positive Displacement
1
Results may vary due to application variations
2
Unleaded Fuel Kit required (Part No 139500-15)
Note: Field Calibration is available on all models.