4. ACPM: Average Count Per Minute reading from this Geiger Counter(optional).
5. uSv: uSv/h reading from this Geiger Counter(optional).
Followings are valid data submission examples:
http://www.GMCmap.com/log2.asp?AID=0230111&GID=0034021&CPM=15&ACPM=13.2&uSV=0.075
http://www.GMCmap.com/log2.asp?AID=0230111&GID=0034021&CPM=15&ACPM=0&uSV=0
http://www.GMCmap.com/log2.asp?AID=0230111&GID=0034021&CPM=15&ACPM=0&uSV=0
http://www.GMCmap.com/log2.asp?AID=0230111&GID=0034021&CPM=15
http://www.GMCmap.com/log2.asp?AID=0230111&GID=0034021&CPM=15&ACPM=13.2
The result will be returned immediately.
The following are the returned result examples:
1. OK.
2. Error! User is not found.
3. Error! Geiger Counter is not found.
4. Warning! The Geiger Counter location changed, please confirm the location.
If a location change warning received, the user will need to confirm the location from that Geiger Counter
profile OR create another Geiger Counter from your account. In this case, you can have two locations
share one Geiger Counter.
Applications
Stationary Application
The unit can be placed to almost anywhere for stationary monitoring of radiation and long-term surveillance
applications. With the wall adapter, it is able to monitor the data continuously, 24/7.
Other Important Technical Details
USB Port
The USB port is the standard mini-USB port. It is used for data communication, external power and the
battery charger connection.
Data collection time
The GMC-800 radiation data is collected continuously, and every second the measured data is being
transmitted to the CPU for processing.
Extend battery operating time
Turn on the Power Saving mode to extend the battery operating time. Turn off the speaker if it is not
necessary. If a fully charged battery run-out in less than 3 operating hours, then the battery needs to be
replaced. Use a standard 14500 (14 x 50.0 mm) 3.6V-3.7V Li battery OR 14500 (14 x 50.0 mm) 3.6V-3.7V
rechargeable Li-ion battery.
The GMC-800 will operate normally when a non-rechargeable battery is installed. Select the battery type to
non-rechargeable battery from the unit menu.