Pressure Relief
6 334599L
2. Turn the ON/OFF switch to OFF posi-
tion. Wait 7 seconds for power to dissi-
pate.
3. Unplug power cord or shut engine off.
For LineLazer ES 1000, unplug power
cord and disconnect battery.
4. Engage the trigger lock.
5. Remove tip guard.
6. Turn pressure control to the lowest set-
ting. Disengage trigger lock.