Operation
Husky
®
1050 Air-Operated
Diaphragm Pump
312877ZAD
EN
1-inch pump with modular air valve for fluid transfer applications. For professional use
only.
See page 4 for model information, including approvals.
125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure
125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure
Center
Flange
ti13844a
ti13843a
End
Flange
1050P Polypropylene
1050C Conductive
Polypropylene
1050F PVDF
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
1050S Stainless Steel
1050H Hastelloy
ti14342a
1050A Aluminum
ti13946a

Other manuals for Graco Husky 1050

Questions and Answers

  • R
    rasmussenlisaAug 3, 2025
    How to fix a Graco Husky 1050 that cycles but won't prime?
    • C
      Christian MontgomeryAug 3, 2025
      If the Graco Water Pump cycles but won't prime, first check if the pump is running too fast; lower the air inlet pressure. Also, inspect for clogs in the outlet or inlet and unclog them if necessary. Ensure that the inlet and outlet valves are open and that the inlet fittings or manifolds are tightened. If the manifold o-rings are damaged, replace them. Finally, a severely worn or wedged check valve ball, seat, or a severely worn seat may be the cause, requiring replacement.
  • F
    Fernando HansonAug 10, 2025
    What to do if Graco Husky 1050 will not cycle, or cycles once and stops?
    • J
      Jack GrantAug 10, 2025
      If your Graco Water Pump will not cycle, or cycles once and stops, the air valve may be stuck or dirty. Disassemble and clean the air valve, ensuring you use filtered air. Another possible cause is a severely worn check valve ball wedged in the seat or manifold, which would require replacing the ball and seat. Additionally, the pilot valve could be worn, damaged, or plugged, necessitating its replacement. Other potential issues include a damaged air valve gasket (replace the gasket), a check valve ball wedged into the seat due to overpressurization (install a pressure relief kit), a clogged dispensing valve (relieve pressure and clear the valve), or plugged air tubing (clear the tube).
  • A
    Anthony LopezAug 18, 2025
    Why does my Graco Husky 1050 operate erratically?
    • R
      Robin MyersAug 18, 2025
      If the Graco Water Pump operates erratically, start by inspecting and clearing any clogs in the suction line. Check valve balls may be sticky or leaking, requiring cleaning or replacement. Other potential causes include a ruptured diaphragm (and backup), which needs replacement, or a restricted exhaust, which needs to be removed. Damaged or worn pilot valves or a damaged air valve or air valve gasket may also cause erratic operation, requiring replacement. Additionally, an erratic air supply should be repaired. Finally, exhaust muffler icing can cause issues, which can be resolved by using a drier air supply or a low ice muffler (Graco part 102656).
  • R
    Rachel FisherAug 26, 2025
    What causes a Graco Husky 1050 to cycle at stall or fail to hold pressure?
    • R
      rachelmooneyAug 26, 2025
      If your Graco Water Pump cycles at stall or fails to hold pressure at stall, worn check valve balls, seats, or o-rings are likely the cause. Replacement is needed.

Summary

Distributor Information

Specify Pump Configuration

Guide to specifying the correct pump configuration for new purchases.

Pump Matrix

Safety and Certifications

ATEX Certifications

Information regarding ATEX certifications for pump models.

General Warning Information

Critical safety warnings for operation and handling.

Installation

Mounting and Grounding

Equipment Grounding

Essential grounding instructions to prevent static discharge hazards.

Operation

Pressure Relief Procedure

Steps to safely relieve pressure before maintenance or shutdown.

Pump Priming and Adjustment

Guide to properly starting, priming, and adjusting pump operation.

Maintenance

Performance Charts

Technical Specifications

Operating Parameters

Key operating parameters including pressure, flow, and speed.

Warranty and Information

Graco Pump Warranty Details

Details of the manufacturer's warranty for Graco pumps.

Graco Husky 1050 Specifications

General IconGeneral
Maximum Flow Rate50 gpm (189 lpm)
Fluid Inlet/Outlet Size1 in npt(f)
Maximum Suction Lift6.1 m
Wetted PartsStainless Steel, Polypropylene, Acetal
Diaphragm MaterialsBuna-N
Power SourceAir Operated
Pump TypeAir-Operated Double Diaphragm