EasyManua.ls Logo

Graco Husky 1050 - Fluid Supply Line; Fluid Outlet Line

Graco Husky 1050
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
12 312877ZAD
Fluid Supply Line
See FIG. 4, page 13.
1. Use grounded, flexible fluid supply lines (G). See
Grounding, page 9.
2. If the inlet fluid pressure to the pump is more than
25% of the outlet working pressure, the ball check
valves will not close fast enough, resulting in
inefficient pump operation. Excessive inlet fluid
pressure also will shorten diaphragm life.
Approximately 3 - 5 psi (0.02- 0.03 MPa, 0.21-0.34
bar) should be adequate for most materials.
3. For maximum suction lift (wet and dry), see
Technical Specifications, page 25. For best
results, always install the pump as close as possible
to the material source.
Fluid Outlet Line
See FIG. 4, page13.
1. Use grounded, flexible fluid hoses (L). See
Grounding, page 9.
2. Install a fluid drain valve (J) near the fluid outlet.
3. Install a shutoff valve (K) in the fluid outlet line.