Installation
– Increasing Spring T
ension
Increasing Spring Tension
1. Pull
the hose out fully
, and engage the latch.
2.
Remove the dispensing valve (not shown) and the
hose stop (47). See Fig. 10.
3.
Pull the hose (48) back through the hose rollers
(22). See Fig. 10.
4. W
rap a loop of hose onto the reel flange (40).
5.
Check the spring tension; the hose must pull out
fully and retract fully
. W
rap more loops, one at a
time, around the reel flange until the spring has the
desired tension.
NOTE:
Do not put so many loops onto the reel that the
spring winds up tightly before the hose is fully
extended. Remove loops to decrease tension.
CAUTION
A spring that is wound too tightly prevents the hose
from getting pulled out all the way
, which puts
excessive strain on the hose and reel spring and
could damage the reel.
6.
Route the hose through the hose rollers and
reinstall the hose stop (S) and dispensing valve.
See Fig 10.
Fig. 10
DET
AIL A – Hose Inlet Kits
J
K
L
304
45
34
302
301
H
1641
1642
403
402
1/2
npt(m)
1/2 npt(f)
401
404
48
49
22
40
Model
219–097 only
T
o supply line
Position
hose stop (47)
for
operator
s reach
303

Related product manuals