EasyManua.ls Logo

Graco Triton 308 - User Manual

Graco Triton 308
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1:1 RATIO
TRITON
R
308
Diaphragm Pump
Used to pump waterborne and solvent–based paints and catalysts.
115 psi (0.8 MPa, 8 bar) Maximum Fluid Working Pressure
115 psi (0.8 MPa, 8 bar) Maximum Air Input Pressure
Part No. 233500 Aluminum Pump, Series D, npt threads
Part No. 233501 Stainless Steel Pump, Series C, npt threads
Part No. 233776 Aluminum Pump, Series C, BSPP threads
Part No. 233777 Stainless Steel, Series C, BSPP threads
U.S. and Foreign Patents Pending
Instructions–Parts List
309303T
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
ti1029a
Part No. 233501 Shown

Other manuals for Graco Triton 308

Questions and Answers

  • J
    Jennifer SmithAug 18, 2025
    What to do if there is fluid in the exhaust air of Graco Water Pump?
    • D
      Dr. Linda AguirreAug 19, 2025
      If you notice fluid in the exhaust air of your Graco Water Pump, it's likely due to a ruptured diaphragm. The solution is to replace the diaphragms.
  • M
    Mark HallAug 22, 2025
    How to fix air bubbles in fluid from Graco Water Pump?
    • S
      Summer RayAug 22, 2025
      If you observe air bubbles in the fluid of your Graco Water Pump, the issue could stem from a loose suction line. Try tightening it, and use a compatible liquid thread sealant on the connections. Alternatively, the diaphragm might be ruptured, requiring replacement.
  • M
    Mary SullivanAug 25, 2025
    What causes Graco Triton 308 to run erratically?
    • A
      Andre HerringAug 26, 2025
      If your Graco Water Pump runs erratically, the problem may be a clogged suction line or inlet strainer. Clear any blockages. Another potential cause is sticking or leaking ball check valves. Disassemble and clean the ball checks, and replace any worn parts.
  • O
    Omar McneilAug 27, 2025
    Why Graco Water Pump cycles at stall or fails to hold pressure?
    • J
      John JacksonAug 28, 2025
      If your Graco Water Pump cycles at a stall or fails to hold pressure at a stall, it is likely due to worn ball check valves. To resolve this, disassemble and clean the ball checks, replacing any worn parts.
  • N
    Nicholas RamirezAug 31, 2025
    How to troubleshoot poor finish from Graco Triton 308 Water Pump?
    • S
      Stephanie ArnoldAug 31, 2025
      A poor finish or irregular spray pattern from your Graco Water Pump can arise from several factors. The fluid or air pressure at the gun might be incorrect, so consult the gun manual and fluid manufacturer’s recommendations, and use a fluid regulator. The fluid might be too thin or too thick, requiring you to adjust the fluid viscosity according to the fluid manufacturer’s recommendations. A dirty, worn, or damaged spray gun could also be the culprit, so service the gun. Lastly, the fluid might be settling out, in which case you should use an agitator.
  • J
    jeanne78Sep 3, 2025
    What to do if Graco Triton 308 runs too fast?
    • M
      Mary WhiteSep 3, 2025
      If your Graco Water Pump runs too fast, it's likely because the fluid supply is exhausted. Refill the fluid supply and prime the pump.
  • S
    Sean HarrisSep 6, 2025
    Why is air exhausting from the mounting holes of my Graco Water Pump?
    • R
      Robert SmithSep 6, 2025
      If air is exhausting from the mounting holes of your Graco Water Pump, it indicates that the fluid covers are installed incorrectly. Align the mounting holes in the fluid covers with the holes in the center housing.
  • P
    pcamachoSep 9, 2025
    How to stop audible air leak in Graco Triton 308 Water Pump?
    • C
      Christina HuynhSep 9, 2025
      If you hear an audible air leak in your Graco Water Pump, it's likely due to a worn air valve cup or plate. To address this, service the air valve.
  • T
    Tyler UnderwoodSep 12, 2025
    What causes Graco Triton 308 Water Pump to run sluggishly?
    • D
      Debra GeorgeSep 12, 2025
      If your Graco Water Pump runs sluggishly, it could be due to worn or damaged carriage o-rings. Service the air valve.
  • R
    rboltonNov 14, 2025
    Why my Graco Triton 308 will not run?
    • S
      Samuel GutierrezNov 15, 2025
      If your Graco Water Pump won't run, there are several potential causes: * The air line valve might be closed. If so, open the valve. * There may be an inadequate air supply or a clogged/restricted air line. Increase the air supply, ensuring you do not exceed the maximum air inlet pressure. Open or clear the air line. * The air filter might be dirty. Clean the air filter. * The pump, fluid line, or spray gun could be clogged. Clear and service them, and flush regularly. Prevent fluid from setting up in the pump and lines. * The pump air valve may be stuck or damaged. Disassemble and clean the air valve, replacing worn parts. Use filtered air. * The diaphragm might be ruptured. Replace the diaphragms. * The air valve plate could be installed incorrectly. Align the plate with t...

Summary

Equipment Misuse Hazard

Fire and Explosion Hazard

Pressurized Fluid Hazard

Toxic Fluid Hazard

Installation

Grounding

Instructions for grounding pump and equipment to reduce static sparking risks.

Operation

Pressure Relief Procedure

Steps to safely relieve system pressure before servicing or stopping operation.

Starting and Adjusting the Pump

Procedure for priming the pump, including safety checks and regulator adjustment.

Troubleshooting

Service

Ball Check Repair

Procedure for repairing or replacing ball checks, including disassembly and reassembly.

Diaphragm Repair

Instructions for replacing pump diaphragms, including safety precautions and tools.

Air Valve Repair

Detailed steps for disassembling and reassembling the air valve assembly.

Parts

Technical Data

Graco Triton 308 Specifications

General IconGeneral
BrandGraco
ModelTriton 308
CategoryWater Pump
LanguageEnglish

Related product manuals