EasyManua.ls Logo

Graco FieldLazer R300 - User Manual

Graco FieldLazer R300
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ti6394a
311017E
EN FR ES PT
Operation / Fonctionnement /
Funcionamiento / Funcionamento
LineLazer
IV 3900, 5900, FieldLazer R300
Airless Line Stripers / Traceurs de ligne airless / Señalizadoras/
Kit de marcação de baiasAirless (de alta pressão)
- For the application of line striping materials -
- Pour tracer des lignes à la peinture -
- Para la aplicación de materiales trazalíne -
- Para aplicação de materiais de marcação de baias -
3300 psi (22.8 MPa, 228 bar) Maximum Working Pressure /
Pression de service maximum 3300 psi (22,8 MPa, 228 bars) /
Presión máxima de trabajo de 3300 psi (22,8 MPa, 228 bar) /
Pressão de trabalho máxima de 3300 psi (22,8 MPa, 228 bar)
Important Safety Instructions
Read all warnings and instructions in
thismanual. Save these instructions.

Other manuals for Graco FieldLazer R300

Questions and Answers

  • A
    ajensenNov 23, 2025
    What to do if Graco Construction Equipment pump output is low?
    • L
      laura92Nov 23, 2025
      If the pump output on your Graco Construction Equipment is low, consider the following: * The strainer is clogged: Clean the strainer. * The piston ball is not seating: Service the piston ball. * The piston packings are worn or damaged: Replace the packings. * The O-ring in the pump is worn or damaged: Replace the O-ring. * The intake valve ball is not seating properly or is packed with material: Clean the intake valve. * The engine speed is too low: Increase the throttle setting. * The clutch is worn or damaged: Replace the clutch. * The pressure setting is too low: Increase the pressure. * The fluid filter, tip filter, or tip is clogged or dirty: Clean the filter. * There is a large pressure drop in the hose with heavy materials: Use a larger diameter hose and/or red...
  • M
    Mary GibsonAug 26, 2025
    What to do if fluid is spitting from my Graco Construction Equipment gun?
    • B
      bmoranAug 27, 2025
      If fluid is spitting from the gun of your Graco Construction Equipment, here are a few things to check: * There's air in the pump or hose: Check and tighten all fluid connections, then reprime the pump. * The tip is partially clogged: Clear the tip. * The fluid supply is low or empty: Refill the fluid supply and prime the pump. Make sure to check the fluid supply often to prevent the pump from running dry.
  • J
    John CarterAug 27, 2025
    What to do if I see excessive paint leakage into the throat packing nut of my Graco Construction Equipment?
    • D
      Darlene DavisAug 27, 2025
      If you notice excessive paint leakage into the throat packing nut of your Graco Construction Equipment, try these solutions: * The throat packing nut is loose: Remove the throat packing nut spacer and tighten the throat packing nut just enough to stop the leakage. * The throat packings are worn or damaged: Replace the packings. * The displacement rod is worn or damaged: Replace the rod.
  • L
    Lisa CookAug 28, 2025
    What to do if my Graco FieldLazer R300 pump is difficult to prime?
    • I
      Isabel GarnerAug 28, 2025
      If you're having trouble priming the pump on your Graco Construction Equipment, consider the following: * There's air in the pump or hose: Check and tighten all fluid connections. Reduce engine speed and cycle the pump as slowly as possible during priming. * The intake valve is leaking: Clean the intake valve, ensuring the ball seat is not nicked or worn and that the ball seats well. Reassemble the valve. * The pump packings are worn: Replace the pump packings. * The paint is too thick: Thin the paint according to the supplier’s recommendations. * The engine speed is too high: Decrease the throttle setting before priming the pump.
  • N
    Nicole GreenNov 24, 2025
    What to do if my Graco Construction Equipment engine operates, but displacement pump doesn't?
    • M
      Mr. Robert Brown MDNov 24, 2025
      If your Graco Construction Equipment engine operates, but the displacement pump does not, check the following: * The pump switch is OFF: Turn the pump switch ON. * The pressure setting is too low: Turn the pressure adjusting knob clockwise to increase pressure. * The fluid filter is dirty: Clean the filter. * The tip or tip filter is clogged: Clean the tip or tip filter. * The displacement pump piston rod is stuck due to dried paint: Repair the pump. * The connecting rod is worn or damaged: Replace the connecting rod. * The drive housing is worn or damaged: Replace the drive housing. * Electrical power is not energizing the clutch field: Check wiring connections. With the pump switch ON and pressure turned to MAXIMUM, use a test light to check for power between clutch test...
  • C
    caitlinevansSep 15, 2025
    What to do if the distance counter is not operating properly on my Graco Construction Equipment?
    • A
      Amber GreenSep 15, 2025
      If the distance counter on your Graco Construction Equipment is not operating properly, the trigger sensor might not be set correctly. Check the connector and reconnect if there are bad wiring connections. It could also be that the gear teeth are missing or damaged (replace the distance gear/wheel), or the wire is cracked or broken (replace the sensor).
  • J
    James RossSep 13, 2025
    What to do if the gallon counter is not working on my Graco Construction Equipment?
    • J
      Joshua PinedaSep 13, 2025
      If the gallon counter on your Graco Construction Equipment isn't working, check for broken or disconnected wires (check wires and connections, replace broken wires). It could also be due to a bad sensor (replace the sensor) or a missing magnet (reposition or replace the magnet).
  • H
    Heather CharlesSep 14, 2025
    What to do if the sprayer operates, but the display does not on my Graco Construction Equipment?
    • D
      Deborah BrownSep 14, 2025
      If your Graco Construction Equipment sprayer operates but the display doesn't, it could be due to a bad connection between the control board and the display (remove the display and reconnect it). Alternatively, the display might be damaged (replace the display).
  • E
    emily58Sep 6, 2025
    How to fix spray icon not showing on Graco FieldLazer R300 Construction Equipment display when fluid is sprayed?
    • D
      Debra SmithSep 6, 2025
      If the spray icon does not appear on the display when fluid is sprayed from your Graco Construction Equipment, check the following: * Loose connector: Check the connector and reconnect it. * Interrupter is improperly positioned: Turn the screw counterclockwise until the spray icon synchronizes with fluid spray. * Reed switch assembly is damaged: Replace the reed switch assembly. * Magnet on assembly is missing: Replace the reed switch assembly. * Cut or sliced wire: Replace the distance sensor harness. * Control board is damaged: Replace the control board. * Display is damaged: Replace the display.
  • K
    Kristin HollowaySep 3, 2025
    What causes fluid spray to start after spray icon on Graco FieldLazer R300 display?
    • U
      uandersonSep 4, 2025
      If the fluid spray starts after the spray icon is shown on the display of your Graco Construction Equipment, it's likely that the interrupter is improperly positioned. Turn the screw counterclockwise until the spray icon synchronizes with the fluid spray.

Graco FieldLazer R300 Specifications