311020 17
Pressure Control
On/Off Switch
Removal
1. Relieve pressure, page 7.
2. Fig. 13. Remove two screws (125) and cover (31).
3. Pull display connector wings (A) open on PC board
and pull display connector out.
4. Disconnect ON/OFF switch connector (B) from PC
board.
5. Press in on two retaining tabs on each side of
ON/OFF switch (15g) and remove switch.
Installation
1. Install ON/OFF switch (15g) so tabs of switch snap
into place on inside of pressure control housing.
2. Connect ON/OFF switch connector (B) to PC
board.
3. Push display connector into PC board close dis-
play connector wings (A) on PC board.
4. Install cover (31) with two screws (125).
ENGINE
GROUND
ti6408a
Main Control
Box Cable
Transducer
Fig. 13
A
B
15g
125
31
15d
15j
C
216
217
15o 15r
D
15i
15n

Other manuals for Graco FieldLazer R300