For the application of line striping materials.
For professional use only.
For outdoor use only.
Not for use in explosive atmospheres or hazardous locations.
Maximum Operating Speed: 10 mph (16 kph)
Maximum Operating Pressure: 3300 psi (22.8 MPa, 228 bar)
Important Safety Instructions
Read all warnings and instructions in this manual and in related manuals.
Be familiar with the controls and the proper usage of the equipment.
Save these instructions.
Model Guns
Pressurized
Bead System
Description
17H471 2 No LLV 250DC
17H472 3 No LLV 250DC
17H473 2 Yes - 2 Tank LLV 250DC
17H474 3 Yes - 2 Tank LLV 250DC
17H466 1 No LLV 250SPS
17H467 2 No LLV 250SPS
17H468 1 Yes - 1 Tank LLV 250SPS
17J951 2 Yes - 1 Tank LLV 250SPS
17H469 2 Yes - 2 Tank LLV 250SPS
Related Manuals:
3A3394 Repair / Parts
311254 Gun
309277 Pump
3A3428 Auto-Layout Applications Methods
332230 Pressurized Bead System (PBS)
Operation
LineLazer V 250SPS and 250DC
Self-Propelled Line Striper
3A3393C
EN
Use only genuine Graco replacement parts.
The use of non-Graco replacement parts may void warranty.

Other manuals for Graco LineLazer V 250SPS

Questions and Answers

  • L
    Lisa EdwardsSep 23, 2025
    What causes excessive leakage around the hydraulic motor piston rod wiper on Graco Construction Equipment?
    • S
      Shannon ZimmermanSep 23, 2025
      Excessive leakage around the hydraulic motor piston rod wiper indicates a worn or damaged piston rod seal. Replace the hydraulic motor piston rod wiper and seal.
  • A
    Andrea CampbellAug 25, 2025
    How to fix a Graco LineLazer V 250SPS Construction Equipment when the engine will not crank?
    • K
      kbrownAug 25, 2025
      If your Graco Construction Equipment engine won't crank, the battery might be discharged. Try turning the key switch to ON, choking the engine, and pulling the recoil starter rope. If that doesn't work, the key switch itself could be defective and need replacement. Another possibility is a defective main wire harness, which would also require replacement.
  • R
    Russell LopezAug 25, 2025
    What to do if my Graco LineLazer V 250SPS Construction Equipment machine will not drive?
    • A
      Aaron WalkerAug 26, 2025
      If your Graco Construction Equipment isn't driving, first, ensure the engine clutch switch is ON. Check that the hydrostatic drive bypass valve is closed to engage the drive. Also, verify the hydraulic fluid level and add fluid if low. Inspect the drive cable and clutch wire harness for disconnections or breaks, reconnecting or replacing as needed. Other potential issues include a malfunctioning clutch (replace if necessary), a worn or broken ground drive belt (adjust or replace), a faulty ground drive pump (replace), or worn/non-working wheel motor(s) (replace).
  • J
    Jessica WilliamsonAug 27, 2025
    Why is fluid spitting from the gun of my Graco Construction Equipment?
    • A
      Amanda MezaAug 27, 2025
      If fluid is spitting from the gun, it could be due to air in the pump or hose. Check and tighten all fluid connections and reprime the pump. A partially clogged tip can also cause spitting, so clear the tip. Lastly, ensure the fluid supply is adequate; refill if low or empty, and prime the pump. Regularly check the fluid supply to prevent the pump from running dry.
  • H
    Heather WalkerAug 27, 2025
    Why does my Graco LineLazer V 250SPS Construction Equipment engine crank slowly?
    • H
      Heather HarrisAug 27, 2025
      If your Graco Construction Equipment engine cranks slowly, it might be due to excessive hydraulic load. Ensure the engine clutch switch is turned OFF.
  • H
    Hannah GonzalezSep 16, 2025
    Why isn't the gallon counter adding fluid volume on my Graco LineLazer V 250SPS Construction Equipment?
    • G
      Gregory PowellSep 16, 2025
      The gallon counter may not add fluid volume if the fluid pressure isn't high enough; it must be over 800 psi (55 bar) for the counter to function. Check the pump counter wire for breaks or disconnections. A missing or damaged magnet on the pump could also be the problem. Finally, the sensor itself may be bad and need replacement.
  • D
    Debra MooreSep 13, 2025
    What to do if the display on my Graco LineLazer V 250SPS Construction Equipment does not turn on?
    • J
      John GriffinSep 13, 2025
      If the display doesn't turn on, first ensure the key switch is in the ON position. If it still doesn't turn on, the main fuse may be blown and need replacement. Another possibility is a disconnected or damaged cable between the display and main board, which would need reconnection or replacement. Finally, the display board itself may have failed, requiring replacement.
  • L
    Leslie ChavezSep 15, 2025
    What to do if pressure control knob rotates freely with no pressure change in Graco LineLazer V 250SPS?
    • R
      Rose PearsonSep 15, 2025
      If the pressure control knob rotates freely without changing the pressure, the set screw at the hydraulic pump connection may be loose. Alternatively, the remote cable could be broken or disconnected, requiring replacement or reconnection.
  • B
    Barry DuarteSep 5, 2025
    Why isn't the distance adding properly on my Graco Construction Equipment?
    • D
      Diane McgeeSep 6, 2025
      If the distance isn't adding properly, and MEASURE mode is inaccurate, the machine may not be calibrated correctly. Perform the calibration procedure. Also, ensure the rear tire pressure is properly adjusted to 55 +/- 5 psi (380 +/- 34 kPa). Check for missing or damaged gear teeth on the right side (when standing on the platform) and replace the distance gear/wheel hub if needed. Finally, inspect the distance sensor for looseness or damage, and reconnect or replace it as necessary.
  • A
    Andre AlvaradoSep 3, 2025
    Why is the stall or run pressure low on my Graco Construction Equipment display?
    • L
      Lauren RobinsonSep 3, 2025
      A low stall or run pressure on the display might be due to a pressure setting that is too low; turn the pressure adjusting knob clockwise to increase the pressure. If you have a new pump or new packings, keep in mind that the pump break-in period can take up to 100 gallons of material. A faulty transducer could also be the cause, requiring replacement.

Summary

Operation and Safety

Important Safety Instructions

Crucial safety guidelines for operating the equipment safely.

Safety Warnings

Traffic, Fire, and Explosion Hazards

Warnings related to traffic, fire, explosion, and carbon monoxide risks.

Skin Injection Hazard

Danger of high-pressure spray injecting toxins into the body.

Equipment Safety

Carbon Monoxide and Misuse Hazards

Risks from exhaust fumes and improper equipment operation.

Operational Hazards and Protection

Toxic Fluids, Burns, and PPE

Hazards from toxic fluids, burns, and importance of protective equipment.

Setup and Procedures

Grounding and Pressure Relief

Essential safety procedures before starting equipment operation.

Setup and Startup

Cleanup

Smart Control System

Setup and Calibration

Guide to setting language, units, and calibrating the smart control system.

Striping, Measure, and Layout Modes

Explains different modes for striping, measuring, and marking layouts.

Maintenance

Graco LineLazer V 250SPS Specifications

General IconGeneral
EngineHonda GX160
Engine Displacement163 cc
Single GunYes
Nozzle TypeAirless
Airless Pump TypePiston pump
Paint CompatibilityWaterborne and solvent-based paints
Spray Tip CompatibilityGraco RAC IV
Hose Length50 ft (15 m)
Power SourceGasoline
Material CompatibilityPaints and coatings
Max Operating Pressure3300 psi (22.7 MPa)

Related product manuals