For the application of line striping materials.
For professional use only.
For outdoor use only.
Not for use in explosive atmospheres or hazardous locations.
Maximum Operating Pressure: 3300 psi (22.8 MPa, 228 bar)
Important Safety Instructions
Read all warnings and instructions in this manual and in related manuals before using the equipment.
Be familiar with the controls and the proper usage of the equipment.
Save these instructions.
Related Manuals:
3A3390 Parts 309277 Pump
311254 Gun 3A3428 Auto-Layout Applications Methods
LineLazer V 200HS
Standard Series
LineLazer V 200
HS
High Production Series
LineLazer V 200
DC
Operation
LineLazer
V 200HS & 200DC Airless Line Stripers
Standard Series and High Production (HP) Series
3A3426E
EN
Use only genuine Graco replacement parts.
The use of non-Graco replacement parts may void warranty.

Table of Contents

Questions and Answers

  • S
    Stacy ParkerSep 23, 2025
    Why does the gas engine of my Graco Construction Equipment pull hard and won’t start?
    • E
      Eric PriceSep 23, 2025
      If the gas engine of your Graco Construction Equipment pulls hard and won’t start, it could be due to hydraulic pressure being too high. Turn the hydraulic pressure knob counterclockwise to the lowest setting.
  • S
    Sharon MillerAug 25, 2025
    What to do if my Graco LineLazer V 200HS engine operates, but the displacement pump doesn't?
    • N
      Nathan LucasAug 25, 2025
      If your Graco Construction Equipment engine runs but the displacement pump doesn't, there are several potential causes. First, check if the pump valve is OFF and turn it ON. Ensure the pressure setting isn't too low by turning the pressure adjusting knob clockwise to increase pressure. Inspect the fluid filter for dirt and clean it if necessary. Also, check the tip or tip filter for clogs and clean them. If the displacement pump piston rod is stuck due to dried paint, repair the pump. Replace a worn, broken, or off pulley belt. If the hydraulic fluid is too low, shut off the sprayer and add hydraulic fluid. Lastly, if the hydraulic motor isn't shifting, set the pump valve OFF, turn the pressure down, turn the engine OFF, and pry the rod up or down until the hydraulic motor shifts.
  • W
    William OlsonAug 25, 2025
    What to do if my Graco LineLazer V 200HS displacement pump operates, but output is low on downstroke and/or on both strokes?
    • J
      Jennifer KellyAug 26, 2025
      If the displacement pump operates, but the output is low on the downstroke or both strokes, consider these possible causes: the strainer may be clogged (clean it), the O-ring in the pump may be worn or damaged (replace it), the intake valve ball may be packed with material or not seating properly (clean the intake valve), the engine speed may be too low (increase the throttle setting), there may be a suction tube air leak (tighten the suction tube), the pressure setting may be too low (increase pressure), the fluid filter, tip filter, or tip may be clogged or dirty (clean the filter), or there may be a large pressure drop in the hose with heavy materials (use a larger diameter hose and/or reduce the overall length of the hose).
  • N
    nbradshawAug 26, 2025
    What to do if my Graco LineLazer V 200HS is spitting fluid from gun?
    • C
      christina48Aug 27, 2025
      If fluid is spitting from the gun of your Graco Construction Equipment, it could be due to air in the pump or hose. Check and tighten all fluid connections and reprime the pump. Another cause could be a partially clogged tip, so clear the tip. Also, check if the fluid supply is low or empty, and if so, refill the fluid supply and prime the pump. Make sure to check the fluid supply often to prevent running the pump dry.
  • T
    Tim SmithAug 27, 2025
    What to do if my Graco LineLazer V 200HS pump is difficult to prime?
    • R
      Robert AndrewsAug 27, 2025
      If you're finding it difficult to prime the pump on your Graco Construction Equipment, several factors could be at play. First, check for air in the pump or hose by inspecting and tightening all fluid connections. Reduce engine speed and cycle the pump as slowly as possible during priming. Another potential issue is a leaking intake valve; clean the intake valve, ensuring the ball seat is free from nicks or wear and seats well. If the pump packings are worn, they should be replaced. The paint might be too thick, in which case, thin it according to the supplier’s recommendations. Finally, ensure the engine speed isn't too high by decreasing the throttle setting before priming the pump.
  • P
    patricia06Sep 15, 2025
    What to do if my Graco LineLazer V 200HS Construction Equipment spray icon is always shown on display?
    • S
      Sara VanceSep 15, 2025
      If the spray icon is always shown on the display of your Graco Construction Equipment, the interrupter may be improperly positioned. Turn the screw clockwise until the spray icon is synchronized with the fluid spray. Alternatively, the reed switch assembly may be damaged and need replacement.
  • C
    Christopher ContrerasSep 12, 2025
    What to do if my Graco LineLazer V 200HS Construction Equipment fluid spray starts after spray icon is shown on display?
    • K
      Katherine WilsonSep 13, 2025
      If the fluid spray starts after the spray icon is shown on the display of your Graco Construction Equipment, the interrupter may be improperly positioned. Turn the screw counterclockwise until the spray icon synchronizes with the fluid spray.
  • M
    michaelolsonSep 14, 2025
    What to do if my Graco LineLazer V 200HS Construction Equipment spray icon does not show on display when fluid is sprayed?
    • K
      kcolonSep 14, 2025
      If the spray icon does not show on the display when fluid is sprayed on your Graco Construction Equipment, check that the 5-pin connector and reed switch are properly connected, as a loose connector could be the cause.
  • T
    Tonya LawsonSep 5, 2025
    Why is there excessive hydraulic pump noise in my Graco Construction Equipment?
    • M
      Michael StaffordSep 5, 2025
      Excessive hydraulic pump noise in your Graco Construction Equipment is likely due to a low hydraulic fluid level. Shut off the sprayer and add ISO 46 synthetic oil.
  • T
    Tracy MurraySep 2, 2025
    Why is there excessive paint leakage into the throat packing nut of my Graco Construction Equipment?
    • S
      sharplouisSep 2, 2025
      Excessive paint leakage into the throat packing nut of your Graco Construction Equipment can occur if the throat packing nut is loose. Remove the throat packing nut spacer and tighten the throat packing nut just enough to stop the leakage. It could also be caused by worn or damaged throat packings.

Summary

Important Safety Instructions

Warnings

Fire and Explosion Hazard

Describes fire and explosion risks associated with flammable fumes and static sparking.

Skin Injection Hazard

Highlights risks of serious bodily injury from high-pressure spray injection.

Carbon Monoxide Hazard

Warns about the lethal risks of inhaling carbon monoxide from exhaust.

Equipment Misuse Hazard

Covers hazards from operating equipment while fatigued or under the influence.

Pressurized Aluminum Parts Hazard

Warns about chemical reactions and equipment rupture with incompatible fluids.

Moving Parts Hazard

Alerts to dangers of pinching, cutting, or amputating fingers with moving parts.

Entanglement Hazard

Highlights risks of serious injury from entanglement with rotating parts.

Toxic Fluid or Fumes Hazard

Warns of serious injury or death from toxic fluid or fumes exposure.

Burn Hazard

Alerts to the danger of severe burns from hot equipment surfaces and fluids.

Personal Protective Equipment

Recommends appropriate protective gear for safe operation.

Battery Hazard

Details risks associated with battery leakage, explosion, and burns.

Important Laser Information

Laser Light Hazard: Avoid Direct Eye Contact

Provides critical instructions to prevent eye injury from laser exposure.

Laser Radiation Hazard

Details risks of hazardous radiation exposure from improper adjustments.

Tip Selection

Component Identification (LLV 200 HS)

Component Identification (LLV 200 DC)

Grounding Procedure

Pressure Relief Procedure

Setup;Startup

Gun Placement

Cleanup

LineLazer V LiveLook Display (Standard Series)

LineLazer V LiveLook Display (HP Auto Series)

Setup;Information

Maintenance

Troubleshooting

Hydraulic Oil;Filter Change

Technical Specifications (LineLazer V 200 HS Standard Series)

Technical Specifications (LineLazer V 200 HS HP Auto Series)

Technical Specifications (LineLazer V 200 HS HP Reflective Series)

Technical Specifications (LineLazer V 200 DC Standard Series)

Technical Specifications (LineLazer V 200 DC Standard Reflective Series)

Technical Specifications (LineLazer V 200 DC HP Auto Series)

Technical Specifications (LineLazer V 200 DC HP Reflective Series)

Graco LineLazer V 200HS Specifications

General IconGeneral
BrandGraco
ModelLineLazer V 200HS
CategoryConstruction Equipment
LanguageEnglish

Related product manuals