EasyManua.ls Logo

Graco LineLazer V 200HS - User Manual

Graco LineLazer V 200HS
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
For the application of line striping materials.
For professional use only.
For outdoor use only.
Not for use in explosive atmospheres or hazardous locations.
Maximum Operating Pressure: 3300 psi (22.8 MPa, 228 bar)
Important Safety Instructions
Read all warnings and instructions in this manual and in related manuals before using the equipment.
Be familiar with the controls and the proper usage of the equipment.
Save these instructions.
Related Manuals:
3A3390 Parts 309277 Pump
311254 Gun 3A3428 Auto-Layout Applications Methods
LineLazer V 200HS
Standard Series
LineLazer V 200
HS
High Production Series
LineLazer V 200
DC
Operation
LineLazer
V 200HS & 200DC Airless Line Stripers
Standard Series and High Production (HP) Series
3A3426E
EN
Use only genuine Graco replacement parts.
The use of non-Graco replacement parts may void warranty.

Table of Contents

Questions and Answers

  • V
    Veronica Norris MDSep 7, 2025
    What to do if my Graco Construction Equipment line spacing is not accurate?
    • R
      Rachel Mejia DDSSep 8, 2025
      If the line spacing is not accurate on your Graco Construction Equipment, it could be due to a wrong line pattern being loaded; reload the correct pattern. Another possibility is that the machine is out of calibration.
  • M
    Maria ParkerSep 6, 2025
    What to do if my Graco LineLazer V 200HS Construction Equipment sprayer operates, but the display does not?
    • C
      Christina SandersSep 6, 2025
      If your Graco Construction Equipment sprayer is operating, but the display is not, it could be due to a bad connection between the control board and the display. Remove the display and reconnect it. If that doesn't work, the display may be damaged and need to be replaced.
  • M
    michaeldavisAug 22, 2025
    Why won't my Graco Construction Equipment engine start?
    • W
      William NixonAug 22, 2025
      Several factors can prevent your Graco Construction Equipment engine from starting. First, ensure the engine switch is in the ON position. Check if the engine is out of gas and refill the tank if needed. Also, verify the engine oil level and replenish if low. Inspect the spark plug cable for disconnections or damage, and connect or replace the spark plug as necessary. If the engine is cold, use the choke. Make sure the fuel shutoff lever is in the ON position. Finally, if oil is seeping into the combustion chamber, remove the spark plug, pull the starter 3 to 4 times, clean or replace the spark plug, and keep the sprayer upright to avoid oil seepage.
  • J
    Jesse SteeleSep 4, 2025
    What does it mean if low stall or run pressure shown on display of Graco LineLazer V 200HS?
    • Z
      Zachary SmithSep 4, 2025
      If a low stall or run pressure is shown on the display of your Graco Construction Equipment, it could be because the pump or packings are new, and the pump break-in period can take up to 100 gallons of material. Alternatively, a faulty transducer could be the cause, requiring replacement.
  • T
    Tracy MurraySep 2, 2025
    Why is there excessive paint leakage into the throat packing nut of my Graco Construction Equipment?
    • S
      sharplouisSep 2, 2025
      Excessive paint leakage into the throat packing nut of your Graco Construction Equipment can occur if the throat packing nut is loose. Remove the throat packing nut spacer and tighten the throat packing nut just enough to stop the leakage. It could also be caused by worn or damaged throat packings.
  • J
    James HessSep 1, 2025
    What to do if my Graco LineLazer V 200HS fluid delivery is low?
    • P
      powersscottSep 1, 2025
      If the fluid delivery is low in your Graco Construction Equipment, several factors could be responsible. The pressure setting might be too low, so increase it. If a displacement pump outlet filter is used, it could be dirty or clogged, so clean it. Ensure the intake line to the pump inlet is tight. A large pressure drop in the fluid hose could also be the cause, so use a larger diameter or shorter hose.
  • D
    Diane CampbellAug 31, 2025
    What to do if my Graco LineLazer V 200HS Construction Equipment sprayer overheats?
    • L
      Lisa OrtizAug 31, 2025
      If your Graco Construction Equipment sprayer overheats, it could be due to paint buildup on hydraulic components, requiring cleaning. Another cause could be low oil level, needing a refill with ISO 46 synthetic oil.
  • T
    Taylor StevensonAug 30, 2025
    What does it mean if high engine speed at no load on Graco Construction Equipment?
    • E
      emily89Aug 30, 2025
      If your Graco Construction Equipment experiences high engine speed at no load, it could be due to a mis-adjusted throttle setting. Reset the throttle to 3700 - 3800 engine rpm at no load. Alternatively, a worn engine governor could be the cause, requiring replacement or service.
  • K
    Kathleen LiAug 28, 2025
    What to do if my Graco LineLazer V 200HS gallon (liter) counter is not adding fluid volume?
    • M
      Michael LinAug 29, 2025
      If the gallon (liter) counter on your Graco Construction Equipment isn't adding fluid volume, it could be due to several reasons. First, ensure the fluid pressure is high enough, as it must be over 800 psi (55 bar) for the counter to register. Check for broken or disconnected pump counter wires on both pumps and repair or replace them as needed. Also, inspect for a missing or damaged magnet and reposition or replace it on the pump. Lastly, a bad sensor on both pumps could be the issue, requiring sensor replacement.
  • T
    Tim SmithAug 27, 2025
    What to do if my Graco LineLazer V 200HS pump is difficult to prime?
    • R
      Robert AndrewsAug 27, 2025
      If you're finding it difficult to prime the pump on your Graco Construction Equipment, several factors could be at play. First, check for air in the pump or hose by inspecting and tightening all fluid connections. Reduce engine speed and cycle the pump as slowly as possible during priming. Another potential issue is a leaking intake valve; clean the intake valve, ensuring the ball seat is free from nicks or wear and seats well. If the pump packings are worn, they should be replaced. The paint might be too thick, in which case, thin it according to the supplier’s recommendations. Finally, ensure the engine speed isn't too high by decreasing the throttle setting before priming the pump.

Summary

Important Safety Instructions

Warnings

Fire and Explosion Hazard

Describes fire and explosion risks associated with flammable fumes and static sparking.

Skin Injection Hazard

Highlights risks of serious bodily injury from high-pressure spray injection.

Carbon Monoxide Hazard

Warns about the lethal risks of inhaling carbon monoxide from exhaust.

Equipment Misuse Hazard

Covers hazards from operating equipment while fatigued or under the influence.

Pressurized Aluminum Parts Hazard

Warns about chemical reactions and equipment rupture with incompatible fluids.

Moving Parts Hazard

Alerts to dangers of pinching, cutting, or amputating fingers with moving parts.

Entanglement Hazard

Highlights risks of serious injury from entanglement with rotating parts.

Toxic Fluid or Fumes Hazard

Warns of serious injury or death from toxic fluid or fumes exposure.

Burn Hazard

Alerts to the danger of severe burns from hot equipment surfaces and fluids.

Personal Protective Equipment

Recommends appropriate protective gear for safe operation.

Battery Hazard

Details risks associated with battery leakage, explosion, and burns.

Important Laser Information

Laser Light Hazard: Avoid Direct Eye Contact

Provides critical instructions to prevent eye injury from laser exposure.

Laser Radiation Hazard

Details risks of hazardous radiation exposure from improper adjustments.

Tip Selection

Component Identification (LLV 200 HS)

Component Identification (LLV 200 DC)

Grounding Procedure

Pressure Relief Procedure

Setup;Startup

Gun Placement

Cleanup

LineLazer V LiveLook Display (Standard Series)

LineLazer V LiveLook Display (HP Auto Series)

Setup;Information

Maintenance

Troubleshooting

Hydraulic Oil;Filter Change

Technical Specifications (LineLazer V 200 HS Standard Series)

Technical Specifications (LineLazer V 200 HS HP Auto Series)

Technical Specifications (LineLazer V 200 HS HP Reflective Series)

Technical Specifications (LineLazer V 200 DC Standard Series)

Technical Specifications (LineLazer V 200 DC Standard Reflective Series)

Technical Specifications (LineLazer V 200 DC HP Auto Series)

Technical Specifications (LineLazer V 200 DC HP Reflective Series)

Graco LineLazer V 200HS Specifications

General IconGeneral
BrandGraco
ModelLineLazer V 200HS
CategoryConstruction Equipment
LanguageEnglish

Related product manuals