LineLazer V LiveLook Display
46 3A3426EOperation
Information
Use to select Setup/Information. Press to
open Information Menu.
Displays and logs life data and striper information.
View and test functionality of component
Logs last four error codes that occurred.
Code Description
02 = Over pressure
03 = No transducer detected
Reset error codes
Stroke Counter
Pressure Transducer
Distance Sensor
Touch Pad Buttons
Engine Voltage
Battery Voltage
Clutch
Solenoid 1
Solenoid 2
Battery charger state