Selecting the Correct Tip
24 311910B
Selecting the Correct Tip
FinishPro 390
FinishPro 395
Material Oil Based Water Based Tip Size Fluid Setting Air Setting
Stains/Varnish
✔✔
.008/.010 500-700 psi
(30-50 bar)
1/2 turn
Lacquers
✔✔
.008/.010 700-1000 psi
(50-70 bar)
1/2 turn
DTM
.010/.012 900-1200 psi
(60-80 bar)
1 turn.
DTM (Alkyd)
.014/.016 1800-2400 psi
(125-165 bar)
2 turns
Enamels
✔✔.014/.016 1800-2400 psi
(125-165 bar)
3 turns
Material Oil Based Water Based Tip Size Fluid Setting Air Setting
Stains/Varnish
✔✔
.008/.010 500-700 psi
(30-50 bar)
10 - 15 psi
(0.8 - 1.0 bar)
Lacquers
✔✔
.008/.010 700-1000 psi
(50-70 bar)
10 - 15 psi
(0.8 - 1.0 bar)
DTM
.010/.012 900-1200 psi
(60-80 bar)
15 - 20 psi
(1.0 - 1.5 bar)
DTM (Alkyd)
.014/.016 1800-2400 psi
(125-165 bar)
20 - 25 psi
(1.5 - 1.8 bar)
Enamels
✔✔
.014/.016 1800-2400 psi
(125-165 bar)
25 - 30 psi
(1.8 - 2.0 bar)