FIG. 15: Timing Diagram Example - Request and Dispense Shot #3
TIME (milliseconds)
15 12045 75 10560 90 180 280 330
Pin #9: Ready Status
Pin #8: Dispense Request
Pin #7: Shot Number or Sequence
n
th
Shot Request
1234
4 X 15 mS
100 mS
50 mS
Dispensing begins
Not Grounded
Grounded
Not Grounded
Grounded
24V signal
< 5V signal
300
15 mS 15 mS 15 mS 15 mS 15 mS 15 mS 15 mS