Grounding Instructions
3A1222B 5
Grounding Instructions
1. This sprayer requires 220-240 VAC, 50/60 Hz 10A
circuit with a grounding receptacle. Never use an
outlet that is not grounded.
2. Do not use sprayer if electrical cord has damaged
ground prong.
3. Do not use an extension cord with damaged ground
plug.
Recommended extension cords:
•15 m (49.2 ft) 1.0 mm
2
•30 m (98.4 ft) 1.5 mm
2
•50 m (164.0 ft) 2.5 mm
2
4. Smaller gauge or longer extension cords may
reduce sprayer performance.
Thermal Overload
Motor has a thermal overload switch to shut itself down
if overheated. If unit overheats, allow approximately 45
minutes for unit to cool. Once cool, switch will close and
unit will restart.
ti7529b
ti7528a
To reduce risk of injury from motor starting unexpect-
edly when it cools, always turn power switch OFF if
motor shuts down.