Warnings
332689D 5
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent, in work area can ignite or explode. To help prevent fire and explo-
sion:
Use equipment only in well ventilated area.
Sprayer generates sparks. When flammable liquids are used near the sprayer or for flushing or
cleaning, keep sprayer at least 20 feet (6 meters) away from explosive vapors.
Keep work area free of debris, including solvent, rags and gasoline.
Ground equipment in the work area. See Grounding instructions.
Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment
until you identify and correct the problem.
Keep a working fire extinguisher in the work area.
SKIN INJECTION HAZARD
High-pressure Spray Is Able To Inject Toxins Into The Body And Cause Serious Bodily Injury. In The
Event That Injection Occurs, Get Immediate Surgical Treatment.
Do Not Aim The Gun At, Or Spray Any Person Or Animal.
Keep Hands And Other Body Parts Away From The Discharge. For Example, Do Not Try To Stop
Leaks With Any Part Of The Body.
Always Use The Nozzle Tip Guard. Do Not Spray Without Nozzle Tip Guard In Place.
Use Graco Nozzle Tips.
Use Caution When Cleaning And Changing Nozzle Tips. In The Case Where The Nozzle Tip Clogs
While Spraying, Follow The Pressure Relief Procedure For Turning Off The Unit And Relieving
The Pressure Before Removing The Nozzle Tip To Clean.
Equipment maintains pressure after power is shut off. Do not leave the equipment energized or
under pressure while unattended. Follow the Pressure Relief Procedure before the equipment is
unattended or not in use, and before servicing, cleaning or removing parts.
Check Hoses And Parts For Signs Of Damage. Replace Any Damaged Hoses Or Parts.
This System Is Capable Of Producing 3000 Psi. Use Graco Replacement Parts Or Accessories
That Are Rated A Minimum Of 3000 Psi.
Always Engage The Trigger Lock When Not Spraying. Verify The Trigger Lock Is Functioning
Properly.
Verify That All Connections Are Secure Before Operating The Unit.
Know How To Stop The Unit And Bleed Pressure Quickly. Be Thoroughly Familiar With The
Controls.
WARNINGWARNINGWARNING
WARNING

Other manuals for Graco Magnum X5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Magnum X5 and is the answer not in the manual?

Graco Magnum X5 Specifications

General IconGeneral
TypeAirless Paint Sprayer
Maximum Flow Rate0.27 gallons per minute
Maximum Tip Size0.015 inch
Maximum Operating Pressure3000 PSI
Power SourceElectric
Voltage120V
Maximum Hose Length75 ft
Pressure ControlAdjustable
Recommended Annual Use125 gallons per year
Motor0.5 HP