Why does my Graco Industrial Equipment have no hose heat or low hose heat?
- WWhitney RiceNov 24, 2025
Several factors can cause low or no hose heat: * Loose electrical connections: Check and repair hose electrical connections. * Tripped circuit breakers: Reset breakers CB1 or CB2. * Hose zone: Ensure the hose zone is turned on by pressing the zone key. * Temperature settings: Verify A and B temperature setpoints and the hose temperature setpoint are appropriately set and increase if needed. * Temperature control board: Check if the board LED is blinking; if not, check power connections. If the board has power but the LED isn't blinking, replace the board. * Flow rate: Use a smaller mix chamber or decrease pressure if the flow is too high. * FTS installation: Install the FTS if it is not installed. * Heat-up time: Allow sufficient time for the hose to heat up, or preheat th...