332144E
EN
Instructions-Parts
Reactor
®
E-10hp
For spraying or dispensing polyurea coatings and polyurethane foam. For professional
use only.
Not approved for use in explosive atmospheres or hazardous locations.
3000 psi (21 MPa, 207 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
ti21488a

Questions and Answers

  • S
    Seth MillerSep 23, 2025
    Why is control of primary heat abnormal on my Graco Reactor E-10hp?
    • J
      Joshua SmithSep 23, 2025
      Abnormal control of primary heat, such as high temperature overshoots or intermittent E01 errors, can be caused by dirty thermocouple connections. Examine the connection of thermocouples to the long green plug on the heater control board, unplug and re-plug the thermocouple wires, cleaning off any debris. Another cause is the thermocouple not contacting the heater element. Loosen the ferrule nut, push in the thermocouple so the tip contacts the heater element, and tighten the ferrule nut 1/4 turn past tight. Other potential causes include a failed heater element, signal failure from the thermocouple, or the thermocouple being wired incorrectly.
  • B
    burnettbryanAug 25, 2025
    What to do if my Graco Reactor E-10hp Paint Sprayer fan is not working?
    • K
      kayleemayerAug 26, 2025
      If the fan isn't working, check the fan wire to make sure it's not loose. If the fan is defective, replace it.
  • H
    Harold GallegosAug 26, 2025
    What causes excessive current draw in my Graco Reactor E-10hp?
    • G
      Gary EatonAug 26, 2025
      Excessive current draw can occur for several reasons. First, try shutting off the unit and retrying operation, as the brushes may not be fully seated. Also, check the fan operation, as elevated temperature can cause excessive current draw. A locked rotor (motor unable to turn) can also cause this issue, requiring motor replacement. Lastly, disconnect the motor connections from the control board and cycle power. If status code 5 is still present, replace the board; otherwise, test the motor.
  • J
    Jaclyn RoblesAug 27, 2025
    What to do if my Graco Reactor E-10hp Paint Sprayer has high motor temperature?
    • M
      morgan22Aug 27, 2025
      If the motor temperature is too high, you can try the following: * Reduce the pressure duty cycle, gun tip size, or move the Reactor to a cooler location, and allow 1 hour for cooling. * Check the fan operation and clean the fan and motor housing. * Check the J9 overtemperature connector on the control board.
  • D
    Douglas BrayNov 22, 2025
    What to do if my Graco Paint Sprayer motor does not operate?
    • N
      Nicholas CummingsNov 22, 2025
      If the motor isn't operating, here are some things to check: * If power was turned on while the function knob was set to a run position, set the function knob to Stop/Park until the status LED turns on, then select the desired function. * Inspect the motor power connections on the bottom board for any looseness. * Inspect the brushes for wear, and replace them if they are worn to less than 1/2 in. (13 mm). * Examine the brush springs for breakage or misalignment; realign or replace them as necessary. * Ensure that brushes or springs are not binding in the brush holder; clean the brush holder and align brush leads for free movement. * Check the motor commutator for burn spots, black pitting, or other damage. * If the armature is shorted, replace the motor. * If the control ...
  • S
    Scott LewisSep 14, 2025
    What to do if only one side of my Graco Paint Sprayer doesn’t come up to pressure in spray mode?
    • X
      xfrancisSep 14, 2025
      If only one side doesn't come up to pressure, refill the tank if the fluid level is low. Clean or repair the Recirc/Spray valve if it's dirty or damaged. Clear the fluid inlet strainer if it's plugged. Clean the pump intake valve if it's plugged or stuck open. If the material is too viscous, warm it before adding it to the tanks.
  • W
    William RichmondSep 12, 2025
    What does it mean if my Graco Reactor E-10hp Paint Sprayer status indicator is not lit?
    • O
      osbornenicholasSep 12, 2025
      If the status indicator is not lit, make sure the function knob is set to Park/Off when power is applied. Check that the indicator cable is connected at J3 on the top motor control board. If these steps don't resolve the issue, the control board may have failed and need replacement. A shorted pressure transducer or potentiometer input could also be the cause.
  • S
    smithrobertSep 13, 2025
    What causes pump output to be low on my Graco Reactor E-10hp?
    • E
      Edward BurgessSep 13, 2025
      Low pump output can be caused by a plugged fluid inlet strainer, which needs to be cleared. It can also be due to a leaking or plugged piston valve or intake valve in the displacement pump, in which case the valves should be checked.
  • H
    hrichSep 5, 2025
    What does it mean if my Graco Paint Sprayer has a pressure transducer ISO failure?
    • E
      Erin AyalaSep 5, 2025
      If there is a Pressure Transducer ISO Failure, first check the transducer ISO electrical connection (J11). If that doesn't resolve the issue, reverse the ISO and RES transducer electrical connections at the board. If the error moves to transducer RES (Status Code 4), replace transducer ISO.
  • M
    Michael RogersSep 3, 2025
    What to do if my Graco Reactor E-10hp Paint Sprayer has motor controller faults?
    • B
      Brittany LopezSep 3, 2025
      If you're experiencing motor controller faults, cycle the power. If the error persists, replace the board.

Summary

Safety Warnings and Precautions

Important Isocyanate (ISO) Information

System Overview

Controls and Indicators

Setup Procedures

Startup and Operation

Spraying Procedure

Pause and Refill Operations

Pressure Relief and Shutdown

Maintenance and Flushing

Troubleshooting Guide

Pump Control Status Codes

Interpreting status codes indicated by the system status indicator blinking.

Pressure Deviation from Setpoint

Troubleshooting pressure deviations from the setpoint.

Pressure Transducer ISO Failure

Diagnosing and resolving failures related to the ISO pressure transducer.

Pressure Transducer RES Failure

Diagnosing and resolving failures related to the RES pressure transducer.

Excessive Current Draw

Troubleshooting excessive current draw issues with the motor.

High Motor Temperature

Diagnosing and resolving high motor temperature issues.

No Cycle Counter Switch Input

Troubleshooting issues with the cycle counter switch input.

High Cycle Rate

Addressing problems related to high cycle rates during spraying.

Low Tank Level

Diagnosing and resolving issues related to low material levels in tanks.

Locked Motor Rotor

Troubleshooting a locked motor rotor condition.

Motor Controller Overvoltage

Resolving issues caused by overvoltage to the motor controller.

Motor Controller Undervoltage

Resolving issues caused by undervoltage to the motor controller.

Motor Controller High Temperature

Addressing high temperature issues with the motor controller.

Motor Controller Faults

Troubleshooting general motor controller faults.

DIP Switch Settings

Guide to configuring DIP switch settings for system behavior.

DIP Switch Settings and Functions

Detailed explanation of DIP switch functions and their effects.

Heat Control Diagnostic Codes

Explanation of heat control diagnostic codes and their corrective actions.

No Zone Current

Troubleshooting zero current issues in a specific heater zone.

Thermocouple Disconnected

Diagnosing and resolving issues with disconnected or faulty thermocouples.

Reactor Electronics

Troubleshooting issues related to the reactor's electronic displays and components.

Heater Faults

Diagnosing and resolving problems with the primary heater elements.

Proportioner Issues

Troubleshooting common problems with the proportioner operation.

Repair Procedures

Before Beginning Repair

Essential safety precautions and preparation steps before starting any repair.

Remove Supply Tank

Step-by-step instructions for safely removing a supply tank.

Replace Recirc;Spray Valves

Procedure for disassembling and replacing recirculation/spray valves.

Displacement Pump Repair

Instructions for removing, servicing, and reinstalling the displacement pump.

Control Panel Components

Procedures for replacing display and function knob/potentiometer.

Motor Control Board Replacement

Steps for replacing the motor control board.

Graco Reactor E-10hp Specifications

General IconGeneral
Power SourceElectric
Weight45 lbs
Dimensions25 x 16 x 16 inches
Maximum Fluid Temperature140°F
Heater Voltage120V
Heater Wattage1200W
Hose Length50 ft