332144E
EN
Instructions-Parts
Reactor
®
E-10hp
For spraying or dispensing polyurea coatings and polyurethane foam. For professional
use only.
Not approved for use in explosive atmospheres or hazardous locations.
3000 psi (21 MPa, 207 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
ti21488a

Questions and Answers

  • W
    William RichmondSep 12, 2025
    What does it mean if my Graco Reactor E-10hp Paint Sprayer status indicator is not lit?
    • O
      osbornenicholasSep 12, 2025
      If the status indicator is not lit, make sure the function knob is set to Park/Off when power is applied. Check that the indicator cable is connected at J3 on the top motor control board. If these steps don't resolve the issue, the control board may have failed and need replacement. A shorted pressure transducer or potentiometer input could also be the cause.
  • B
    Brandon AlexanderSep 12, 2025
    What to do if my Graco Reactor E-10hp tank level sensor does not sense full tank?
    • B
      Brandi AlvarezSep 12, 2025
      If the tank level sensor does not sense a full tank, check the position of both tank level sensors to ensure they are properly placed. Reconnect the sensor wires in the display panel if they are disconnected. If problems persist, reset the tank fluid level sensor sensitivity.
  • K
    Kenneth ReeseSep 9, 2025
    What to do if my Graco Reactor E-10hp Paint Sprayer tank level sensor does not sense empty tank?
    • M
      Maurice DavisSep 10, 2025
      If the tank level sensor doesn't sense an empty tank, flush and clean the inside of the tanks and the outside of the sensor and recessed area on the tank to remove any material buildup. Reconnect the LED wires inside the control panel if they are disconnected. If the issue persists, reset the tank fluid level sensor sensitivity.
  • K
    Kelsey ReeseSep 8, 2025
    What to do if my Graco Reactor E-10hp Paint Sprayer has no cycle counter switch input?
    • S
      Shari LopezSep 8, 2025
      If there's no cycle counter switch input, verify that the recirc valves are open and the unit is set to Recirc mode. Check the cycle counter switch connection to the board. Also, check that the magnet and cycle counter switch are in place under the RES side motor end cover, replacing them if necessary.
  • J
    John BlackAug 25, 2025
    What to do if my Graco Paint Sprayer primary heater(s) does not heat?
    • J
      Joshua RodriguezAug 25, 2025
      If the primary heater(s) isn't heating, here's what you can do: * If the heat is turned off, press the zone keys. * Check the temperature display for a diagnostic code if there's a temperature control alarm. * If there is a signal failure from the thermocouple, see E04: Thermocouple disconnected, page 33. * Check the resistance of the heater elements if the heater element has failed.
  • G
    Gilbert MurraySep 6, 2025
    What does it mean if my Graco Paint Sprayer has a pressure transducer RES failure?
    • A
      Ashley WilliamsSep 6, 2025
      If there is a Pressure Transducer RES failure, first check the transducer RES electrical connection (J12). If that doesn't resolve the issue, reverse the ISO and RES transducer electrical connections at the board. If the error moves to transducer ISO (Status Code 3), replace transducer RES.
  • H
    hrichSep 5, 2025
    What does it mean if my Graco Paint Sprayer has a pressure transducer ISO failure?
    • E
      Erin AyalaSep 5, 2025
      If there is a Pressure Transducer ISO Failure, first check the transducer ISO electrical connection (J11). If that doesn't resolve the issue, reverse the ISO and RES transducer electrical connections at the board. If the error moves to transducer RES (Status Code 4), replace transducer ISO.
  • D
    Daniel McclureSep 4, 2025
    What to do if my Graco Paint Sprayer has pressure deviation from setpoint?
    • J
      Jenna HutchinsonSep 4, 2025
      If your equipment cannot maintain enough pressure for a good mix with an impingement mix gun, try using a smaller mix chamber or nozzle.
  • M
    Michael RogersSep 3, 2025
    What to do if my Graco Reactor E-10hp Paint Sprayer has motor controller faults?
    • B
      Brittany LopezSep 3, 2025
      If you're experiencing motor controller faults, cycle the power. If the error persists, replace the board.
  • W
    William BrockSep 1, 2025
    What to do if my Graco Paint Sprayer experiences motor controller high temperature?
    • C
      cynthia55Sep 2, 2025
      If the motor controller indicates a high temperature, shut down the system and move the Reactor to a cooler location. Allow one hour for cooling.

Summary

Safety Warnings and Precautions

Important Isocyanate (ISO) Information

System Overview

Controls and Indicators

Setup Procedures

Startup and Operation

Spraying Procedure

Pause and Refill Operations

Pressure Relief and Shutdown

Maintenance and Flushing

Troubleshooting Guide

Pump Control Status Codes

Interpreting status codes indicated by the system status indicator blinking.

Pressure Deviation from Setpoint

Troubleshooting pressure deviations from the setpoint.

Pressure Transducer ISO Failure

Diagnosing and resolving failures related to the ISO pressure transducer.

Pressure Transducer RES Failure

Diagnosing and resolving failures related to the RES pressure transducer.

Excessive Current Draw

Troubleshooting excessive current draw issues with the motor.

High Motor Temperature

Diagnosing and resolving high motor temperature issues.

No Cycle Counter Switch Input

Troubleshooting issues with the cycle counter switch input.

High Cycle Rate

Addressing problems related to high cycle rates during spraying.

Low Tank Level

Diagnosing and resolving issues related to low material levels in tanks.

Locked Motor Rotor

Troubleshooting a locked motor rotor condition.

Motor Controller Overvoltage

Resolving issues caused by overvoltage to the motor controller.

Motor Controller Undervoltage

Resolving issues caused by undervoltage to the motor controller.

Motor Controller High Temperature

Addressing high temperature issues with the motor controller.

Motor Controller Faults

Troubleshooting general motor controller faults.

DIP Switch Settings

Guide to configuring DIP switch settings for system behavior.

DIP Switch Settings and Functions

Detailed explanation of DIP switch functions and their effects.

Heat Control Diagnostic Codes

Explanation of heat control diagnostic codes and their corrective actions.

No Zone Current

Troubleshooting zero current issues in a specific heater zone.

Thermocouple Disconnected

Diagnosing and resolving issues with disconnected or faulty thermocouples.

Reactor Electronics

Troubleshooting issues related to the reactor's electronic displays and components.

Heater Faults

Diagnosing and resolving problems with the primary heater elements.

Proportioner Issues

Troubleshooting common problems with the proportioner operation.

Repair Procedures

Before Beginning Repair

Essential safety precautions and preparation steps before starting any repair.

Remove Supply Tank

Step-by-step instructions for safely removing a supply tank.

Replace Recirc;Spray Valves

Procedure for disassembling and replacing recirculation/spray valves.

Displacement Pump Repair

Instructions for removing, servicing, and reinstalling the displacement pump.

Control Panel Components

Procedures for replacing display and function knob/potentiometer.

Motor Control Board Replacement

Steps for replacing the motor control board.

Graco Reactor E-10hp Specifications

General IconGeneral
Power SourceElectric
Weight45 lbs
Dimensions25 x 16 x 16 inches
Maximum Fluid Temperature140°F
Heater Voltage120V
Heater Wattage1200W
Hose Length50 ft