Component Identification
6 309665L
Grounding
English
The sprayer must be grounded. Grounding reduces the risk of
static and electric shock by providing an escape wire for the
electrical current due to static build up or in the event of a short
circuit.
• The sprayer cord includes a grounding wire with an appropriate grounding contact. • The plug must be plugged into an
outlet that is properly installed and
grounded in accordance with all
local codes and ordinances.
ti2810a
Power Requirements Extension Cords
• Do not modify plug! If it will not fit
in outlet, have grounded outlet
installed by a qualified
electrician. Do not use an
adapter.
• 100-120V units require
100-120 VAC, 50/60 Hz, 15A,
1 phase.
• 230V units require 230 VAC,
50/60 HZ, 7.5A, 1 phase.
• Use an extension cord with an
undamaged ground contact.
• If an extension cord is necessary,
use a 3-wire, 12 AWG (2.5 mm
2
)
minimum.
ti4297a
Ground
120 volt plug