Temperature-controlled cooling (Hard Chill)
This program cools down to the selected, desired value at full motor
power (controlled with the use of the extra sensor).
Both compressors perform the cooling in parallel. The second
compressor starts 15 seconds after the first one.
The program is selected by pressing the button
:
After pressing the button, it will be lit continuously. The
P
,
+
and
-
buttons will be blinking. The curve symbol
for Hard Chill will light up. The secondary display shows the
program name "PCL", and the tertiary display the selected,
desired temperature value.
The
+
and
-
buttons are used to change the desired
value, and
P
for starting the program.
The primary display will now show the current temperature
in the room, the secondary display the program name "PCL"
and the tertiary display the selected, desired temperature
value. The curve symbol is now continuously displayed. In
addition, the connected elements will now be continuously
lit: both compressors, both fan symbols.
When the desired value is attained, an
acoustic signal will be emitted.
After the signal, defrosting is
commenced (if such is required based
upon the evaporator sensor's
temperature). Then it subsequently
switches to the storage program. Hence
the desired value for the storage
program must always be set and
checked before starting "PCL"!