163
Basic Troubleshooting
Heavy frost buildup on the evaporator fins
Defrost the freezer and refrigerator.
Have the refrigerator checked by your dealer
or a qualified RV technician.
Running Lights
Running lights not working
Blown fuse. Replace fuse with one of the
same ampere rating.
Bad bulbs. Replace the bulbs with new.
Slideout
Room move in and out very slowly,
binds or squeaks
Lubricate the slide-out tubes and rollers with
light spray lube.
Water is getting in at the bottom
corners of the room
Verify exterior seals are against the room at the
top corners and not turned in when the room is out
(horizontal seal overlaps vertical). Also, check for
voids in the seal on the slide roof and side panels.
Make sure weep hole in ramp pan is open
and unobstructed.
Room will not move in or out
Check the auto-resetting fuse located by the
slideout motor. (See the manufacturers manual).
Check battery condition and state of charge.
Recharge if necessary.
Rollers leave tracks in the carpet
as the room extends
This is normal. There are many pounds of weight
pressing these rollers down on the carpet and rollers
will compress the nap of the carpet down. Raking
the nap or vacuuming will solve the problem.