EasyManua.ls Logo

Grandstream Networks GRP260X Series - Page 54

Grandstream Networks GRP260X Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The default setting is “None”.
Config Provision
Download and
Process ALL
Available
Config Files
By default, device will provision the first available config in the order of cfgMAC, cfgMAC.xml, cfgMODEL.xml,
cfg.xml and devMAC.cfg (corresponding to device specific, model specific, and global configs). If set to Yes, device
will download and apply (overwrite) all available configs in the same order.
User Protection When user protection is on, pvalues that user sets will not be changed by provision or provider.
3CX Auto
Provision
Phone will multicast SUBSCRIBE for provision if this feature is enabled.
Advanced Settings
Validate
Hostname in
Certificate
To validate the hostname in the SSL certificate
Enable SIP
Notify
Authentication
Device will challenge NOTIFY with 401 when set to Yes
Factory reset Press Start to begin Factory Reset of the phone.
Maintenance 🡪 System Diagnosis
Syslog
Syslog Protocol
If set to SSL/TLS, the syslog messages will be sent through secured TLS protocol to syslog server.
Default setting is “UDP”.
Note: The CA certificate is required to connect with the TLS server.
Syslog Server
The URL or IP address of the syslog server for the phone to send syslog to.
Note: By adding port number to the Syslog server field (i.e., 172.18.1.1:1000), the phone will send syslog to the
corresponding port of that IP.
Syslog Level
Selects the level of logging for syslog.
The default setting is “None”. There are 4 levels: DEBUG, INFO, WARNING and ERROR.
Syslog messages are sent based on the following events:
Product model/version on boot up (INFO level).
NAT related info (INFO level).
sent or received SIP message (DEBUG level).
SIP message summary (INFO level).
inbound and outbound calls (INFO level).
registration status change (INFO level).
negotiated codec (INFO level).
Ethernet link up (INFO level).
SLIC chip exception (WARNING and ERROR levels).
Memory exception (ERROR level).
Syslog Keyword
Filter
Syslog will be filtered based on keywords provided. If you enter multiple keywords, it should be separated by ‘,’.
Please note that no spaces are allowed.
Send SIP Log
Configures whether the SIP log will be included in the syslog messages. The default setting is “No”.

Other manuals for Grandstream Networks GRP260X Series