Electrical Installation
18
5 Electrical Installation
Figure 5-7: ‘S’ Plan wiring layout
5.7 ‘S’ Plan System Schematic and Wiring Diagram - DuoWave Indirect Solar Cylinder and Boiler
Figure 5-6: ‘S’ Plan system schematic
Boiler
Radiator
Pump
2 port zone valve
(supplied)
Grant DuoWave Indirect
water cylinder
2 port diverter valve
(not supplied)
Cylinder Dual
Thermostat (Top Coil)
230V
50Hz
Room
Thermostat
LNE
2
1
CC
12
1234567
NEL
NE L
N
HTG
HW
L
8910
2
13
Zone valve
DHW
Zone valve
HTG
Blue
Brown
Green/Yellow
Grey
Orange
Grey
Orange
Blue
Brown
Green/Yellow
High limit Con trol
Junction box
Time controller
Boiler
Pump