8.4 Cold Water Flow from Hot Water Taps
Cold Water from Hot Water Taps
Is Programmer calling
for Hot Water?
Check and Set Hot
Water setting
Is Motorised Valve
working?
Is Boiler working?
Is Cylinder Stat
Calling for Heat?
Check Motorised Valve
motor and Micro-switch
Yes
No No No
No Yes
Yes
Yes
Yes
Test for correct operation. If water is still
cold, contact a competent Engineer
Has Thermal Cut-Out
Operated?
Check and Reset
Button
Check and Replace
Cylinder Thermostat
No
Yes