R Series 30934 V2
Operating Manual Page 6
www.grantinstruments.com
To ensure protection the overtemperature cut-out must be set appropriately for
the heat transfer liquid selected (see table below).
If using non-recommended heat transfer liquids it is important to set the over-
temperature cut-out to a value no higher than 25°C below the fire point of the
liquid.
Use fume extraction when using silicone fluids at elevated temperatures
Temp range
Recommended liquid
-50°C to 50°C
Silicone oil low
viscosity
-30°C to 30°C
50% water, 50%
antifreeze (inhibited
ethylene glycol)
0°C to 30°C
80% water, 20%
antifreeze (inhibited
ethylene glycol)
5°C to 99.9°C
Water*
70°C to 120°C
Silicone fluid
Viscosity ~20cs
Flash point ≥230°C
Fire Point ≥280°C
* See section 7.1 for further details