Operating Manual ULTRA DUO PLUS 80
26
[BAT. TEMP TOO HIGH ]
Batt. temperature is too
high to be operated.
[ INTERNAL TEMP ]
Internal temperature is too
hot.
[DATA COMMUNICATION ]
Contact Service.
[BALANCER VOLT. HIGH]
Balancer Voltage is too
high.
[BALANCER VOLT. LOW ]
Balancer Voltage is too
low.
[BALANCER CONNECTOR ]
Selected cells and battery
cells different.
[ NO BALANCER MODE ]
Do not charge LiXX with
this mode.
<NOTICE!!>
Balancer connector
connected.
<NOTICE!!>
Balancer connector
not connected.
Battery temperature too high (this message only appears if the temperature sensor is connected and attached to the
battery). WARNING: if you ignore the warning and charge the battery, it may be damaged! Fire hazard!
The charger has overheated. Allow it cool down, then try again.
This warning appears if a LiXX battery is connected to the balancer output, and the charger detects too high a cell voltage
for the selected battery type. Check the battery type setting and correct if necessary.
This warning is generated if a LiXX battery is connected to the balancer output, and the charger detects too low a cell
voltage for the selected battery type. Check the battery type setting and correct if necessary.
You will see this warning if a LiXX battery is connected to the balancer output, and the charger detects a cell count which
does not match the set cell count. Check the cell count setting and correct if necessary.
You will see this warning if a LiXX battery will not be charged in the LiXX mode. Select the right charging mode.
Note: balancer lead connected to charger.
Note: balancer lead not connected to charger; connect lead.
Communication error. Send the charger to a Graupner service point.