25
Operation procedures/picture
● Screw off the two pieces of screws that fix the
electric box with screwdriver and take out the
water-retaining rubber piece on the evaporator.
Remove the grounding wire on the evaporator and
pull out the tube sensor. Cut off the wire clip with
scissor and unplug the connector terminal of indoor
motor and stepping motor etc. Then unclench the
clasp that fixes the electric box on the rear case to
take out the electric box. (As shown in Fig.8-4)
Fig.8-4
8.1.3 Disassembling the water tray assy
● Screw off the tapping screws that fix the water tray
assy on the left. Push out the clasp in the middle of
the water tray from the rear case and pull out the
water tray assy with strength. Be careful because the
drainage pipe is placed here. (As shown in Fig.8-5)
Tapping screws
Fig.8-5
Screws
Room sensor
Groundin