24
Maintenance
Service Manual
Steps Procedure
10
11
12
13
Remove aspiration and discharge pipes
Unsolder pipe connecting to compressor.
Then remove aspiration and discharge
pipes.
Remove compressor
Remove 3 hold-down nuts of compressor
and then remove compressor.
Remove power cord
Remove 2 screws showing in the picture
and
then remove wire clamp. Then remove
power cord.
Remove castors
Remove 8 connection screws of 4 castors.
Then remove the castors.
nuts
screws
castors
discharge pipe
compressor
aspiration pipe