GMV DC Inverter VRF 
1 
1 Safety Notices (Please be sure to abide) 
WARNING: If not abide them strictly, it may cause severe damage to the unit or the people. 
NOTICE: If not abide them strictly, it may cause slight or medium damage to the unit or the 
people. 
This sign indicates that the operation must be prohibited. Improper operation may cause 
severe damage or death to people. 
This sign indicates that the items must be observed. Improper operation may cause damage 
to people or property. 
WARNING! 
l  This product can't be installed at corrosive, inflammable or explosive environment or the 
place with special requirements, such as kitchen. Otherwise, it will affect the normal 
operation or shorten the service life of the unit, or even cause fire hazard or serious injury. 
As for the above special places, please adopt special air conditioner with anti-corrosive or 
anti-explosion function.   
l  A warning to assure that partial units shall only be connected to an appliance suitable for the 
same refrigerant. 
l  Follow this instruction to complete the installation work. Please carefully read this manual 
before unit startup and service. 
l  This unit <model xxx> is a partial unit air conditioner, complying with partial unit 
requirements of this International Standard, and must only be connected to other units that 
have been confirmed as complying to corresponding partial unit requirements of this 
International Standard. 
l  Installation should be conducted by dealer or qualified personnel. Please do not attempt to 
install the unit by yourself. Improper handling may result in water leakage, electric shock or 
fire disaster etc. 
l  Before using the unit, please check if the pipe and wiring are correct to avoid water leakage, 
refrigerant leakage, electric shock, or fire etc. 
l  Don't climb the outdoor unit, and don't put anything on it. If you fall or turn it over, it will cause 
damage. 
l  Before performing related operations (such as maintenance, inspection, etc.) for the 
equipment, the unit must be turned off and the power supply must be cut off. Moreover, use 
the relevant instrument check whether the voltage at the power input terminal is zero. After 
that, you can perform the operation. Otherwise it will cause electric shock or injury (the unit 
has low-power standby function. Only the main control board indicator is on under standby 
status). 
l  If conducting troubleshooting or maintenance for the modular unit, all outdoor units are 
required to be de-energized or energized at the same time. It's prohibited to energize or 
de-energize some outdoor units.