Multi VRF Floor Standing Indoor Unit
7
Material type
Total length of
communication
line between
indoor unit and
wired controller
L (m/feet)
Wire size
(mm²/AW G)
Material
standard
Remarks
Light/Ordinary
Polyvinyl
chloride
sheathed cord.
(60227 IEC 52
/60227 IEC 53)
L250m
(L820-1/5feet)
2×0.75~2×1.
25
(2×AW G18
~2×AWG16)
IEC
60227
-5:2007
(1)
Total length of
communication
line can't exceed
250m.
(820-1/5feet).
(2)
The cord shall be
Circular cord (the
cores shall be
twisted together).
(3)
If unit is installed
in places with
intense magnetic
field or strong
interference, it is
necessary to use
shielded wire.
3.2.2 Select Communication Line for Indoor Unit and Indoor Unit
(Outdoor Unit)
Fig 3.3