Owner's Manual
Original Instructions
Commercial Air Conditioners
Multi Variable Air Conditioners
Ducted Type Indoor Unit
Models:
GMV-ND22PHS/B-T GMV-ND25PHS/B-T GMV-ND28PHS/B-T GMV-ND32PHS/B-T
GMV-ND36PHS/B-T GMV-ND40PHS/B-T GMV-ND45PHS/B-T GMV-ND50PHS/B-T
GMV-ND56PHS/B-T GMV-ND63PHS/B-T GMV-ND71PHS/B-T GMV-ND80PHS/B-T
GMV-ND90PHS/B-T GMV-ND100PHS/B-T GMV-ND112PHS/B-T GMV-ND125PHS/B-T
GMV-ND140PHS/B-T GMV-ND160PHS/B-T GMV-ND180PHS/B-T

Other manuals for Gree GMV-ND160PHS/B-T

Questions and Answers

  • R
    russell53Aug 18, 2025
    Why is my Gree Air Conditioner not cooling properly?
    • C
      Carrie RamosAug 18, 2025
      If your Gree Air Conditioner isn't cooling well, several factors could be at play. Ensure the filter is clean, as a dirty filter restricts airflow. Reduce the heat load in the room by minimizing the number of people or heat-generating devices. Check that all doors and windows are closed to prevent warm air from entering. Clear any obstructions from the indoor unit's inlet and outlet. Make sure the set temperature isn't too high; lower it for better cooling. Finally, insufficient refrigerant due to leaks can cause poor cooling, so check refrigerant levels and recharge if needed.
  • J
    John NguyenAug 20, 2025
    How to troubleshoot a Gree Air Conditioner that won't start?
    • J
      James MaciasAug 21, 2025
      If your Gree Air Conditioner isn't starting, first, check if the power supply is properly connected. Second, examine the circuit breaker to ensure it hasn't tripped due to a leakage of electricity. Also, make sure the input voltage meets the required level. If none of these steps work, the main PC-board may be defective, and you should contact an authorized service center for repair.
  • K
    Kathryn BradshawAug 23, 2025
    Why is my Gree Air Conditioner not heating well?
    • L
      Lawrence MaloneAug 23, 2025
      If your Gree Air Conditioner's heating isn't effective, start by cleaning or replacing the dirty filter. Ensure all doors and windows are closed to prevent heat loss. If the set temperature is too low, increase it. Also, check for refrigerant leaks and recharge if necessary, as insufficient refrigerant can cause poor heating.
  • J
    jon06Aug 26, 2025
    What to do if my Gree GMV-ND160PHS/B-T stops running after a short time?
    • T
      Tony LyonsAug 26, 2025
      If your Gree Air Conditioner stops after running for a while, it might be because the inlet or outlet of the outdoor (ODU) or indoor unit (IDU) are blocked. Remove any obstacles that are blocking these to ensure proper airflow.
  • K
    Kathleen LawsonAug 27, 2025
    How to fix mode shock in Gree GMV-ND160PHS/B-T Air Conditioner?
    • E
      Eric BlakeAug 28, 2025
      If your Gree Air Conditioner is experiencing mode shock, try resetting the unit to eliminate the mode shock.
  • A
    Amanda RogersAug 29, 2025
    Why doesn't the indoor fan start up on my Gree Air Conditioner during heating?
    • C
      christophermartinAug 30, 2025
      When heating starts, the indoor unit (IDU) fan might not operate immediately. This is to prevent cool air from being delivered until the heat exchange warms up; allow time for the heat exchange to warm up. Also, during defrosting, the IDU fan may stop because the system switches to cooling mode to prevent cool air from being delivered; the fan will resume operating after defrosting is complete.
  • H
    hortontravisSep 1, 2025
    What to do if my Gree GMV-ND160PHS/B-T shows a communication malfunction?
    • M
      Mark MackSep 1, 2025
      If your Gree Air Conditioner displays a communication malfunction, the first step is to check the communication wiring to ensure it is properly connected.
  • G
    Gina MillerSep 3, 2025
    What to do if Gree Air Conditioner shows water overflow protection?
    • J
      jaredmoralesSep 3, 2025
      If your Gree Air Conditioner is experiencing water overflow protection, examine the water drainage system for any blockages that may be causing the issue.
  • J
    Jennifer BaileySep 5, 2025
    Why does my Gree GMV-ND160PHS/B-T show indoor fan protection?
    • W
      westjenniferSep 5, 2025
      If your Gree Air Conditioner displays an indoor fan protection error, ensure the fan is not obstructed or frozen, which may be triggering the protection mechanism.
  • S
    smitholiviaSep 8, 2025
    Why Gree GMV-ND160PHS/B-T Air Conditioner shows freeze prevention protection?
    • R
      Robert ChambersSep 8, 2025
      If your Gree Air Conditioner is showing freeze prevention protection, ensure that the unit is not exposed to extreme cold, as this could trigger the protection mechanism.

Summary

Safety Notices

Installation Instructions

Installation of Indoor Unit

Provides step-by-step instructions for the physical installation of the indoor unit, including dimensions and suspension.

Refrigerant Pipe Connection

Explains the procedure for connecting the refrigerant pipes, including torque specifications.

Drainage Pipe Installation and Drainage System Testing

Guides on drain pipe installation, notices, and comprehensive testing of the drainage system.

Installation of Air Duct

Details the installation of air ducts, including air-out, return air, and fresh air pipes.

Wiring Work

Power Cord Connection

Provides safety and procedural instructions for connecting the power cord to the unit.

Troubleshooting