Air-to-water Heat Pump
7
MONOBLOC
TYPE
maximum and minimum water operating temperatures.
Item
Minimum water operating 
temperatures
Maximum 
water operating 
temperatures
Cooling 7°C 25°C
Heating 25°C 60°C
Water heating 40°C 80°C
maximum and minimum water operating pressures.
Item
Minimum water operating 
pressures
Maximum water 
operating pressures
 Cooling 
0.05MPa 0.25MPaHeating
Water heating
maximum and minimum entering water pressures.
Item
Minimum entering water 
pressures
Maximum entering 
water pressures
 Cooling 
0.05MPa 0.25MPa Heating
Water heating
The range of external static pressures at which the appliance was tested (add-on 
heat pumps, and appliances with supplementary heaters, only); If the supply cord 
is damaged, it must be replaced by the manufacturer, its service agent or similarly 
qualied persons in order to avoid a hazard.
The appliance is intended to be permanently connected to the water mains and not 
connected by a hose-set.
If there is any question, please contact with local dealer, authorized service center, 
agencies or our company directly.