GREE                                                                                                    U-Match 5 SERIES UNIT SERVICE MANUAL
 
123 
 
 
Note: Make sure power is cut off. Take good care of the copper pipe and aluminum fins. If the removal takes a long 
time, seal the copper pipe.   
Remove the evaporator 
assembly. 
 
●
Twist off the 6 screws 
of the evaporator, 3 
screws of the plate 
board of water 
releasing flume, and 2 
screws of the water 
tray. Then remove the 
evaporator.   
Removal of display panel and fan assembly 
Note:  Before  removal,  make  sure  power  is  cut  off.  During  the  removal  procedure,  take  good  care  of  all  the 
components. 
Remove the display 
panel and fan assembly. 
 
●First  remove  the 
display  panel,  next  the 
bracket  and  then  the 
swing  motor  mounting 
plate.   
Note:  Before  removal,  make  sure  power  is  cut  off.  During  the  removal  procedure,  take  good  care  of  all  the 
components, especially the screws of fan.   
●Press the retaining ring at 
the joint of front and rear 
volutes. Then pull up the 
front volute. Then loosen the 
screws of the rear volute. Lift 
up the retaining ring of the 
rear volute and take it off. (As 
shown in the picture, the 
lines indicate the screws on 
both sides of the volutes.   
●Loosen the 2 screws of the 
coupler. Take out the shaft 
and axial flow fan. Loosen 
the screws of axial flow fan 
and remove the axial flow 
fan.