GREE                                                                                                    U-Match 5 SERIES UNIT SERVICE MANUAL
 
73 
 
3.4.39 ―EL‖ Emergency Stop (Fire Alarm) 
If fire alarm terminal is enabled after the IDU mainboard connects to function expansion panel, error EL will be reported.   
3.5 Failures Not Caused by Errors 
(1)If your air conditioner fails to function normally, please first check the following items before maintenance:   
The air conditioner can't run. 
If you turn off the unit and then 
immediately turn it on, in order 
to protect the compressor and 
avoid system overload, 
compressor will delay running 
for 3min.   
Wire connection is wrong. 
Connect wires according to the 
wiring diagram.   
Fuse or circuit breaker is 
broken.   
Replace the fuse or switch on the 
circuit breaker.   
Restart after power is resumed.   
Re-insert the power plug. 
Remote control has low 
battery.   
Bad cooling or heating effect. 
Air inlet and outlet of indoor or 
outdoor units have been 
blocked.   
Clear the obstacles and keep the 
room for indoor and outdoor units 
well ventilated.   
Improper temperature setting 
Reset a proper temperature.   
Reset a proper fan speed.   
Air flow direction is not right.   
Change the direction of air 
louvers.   
Doors or windows are open.   
Exposed under direct sunshine 
Put on curtains or louvers in front 
of the windows.   
Too many heat sources in the 
room.   
Remove unnecessary heat 
sources.   
Filter is blocked or dirty.   
Send for a professional to clean 
the filter.   
Air inlets or outlets of the units 
are blocked.   
Clear away obstacles that are 
blocking the air inlets and outlets 
of indoor and outdoor units.