GREE                                                                                                    U-Match 5 SERIES UNIT SERVICE MANUAL
 
54 
 
3.4.14 ―C5‖ IDU Jumper Cap Error 
Error display: IDU wired control and IDU receiver light board will display C5 
Error judgment condition and method: 
If jumper cap model doesn‗t match with mainboard, this error will be reported. 
Possible reason: 
■Jumper cap is not installed. 
■Jumper cap model is wrong. 
■Detecting circuit is abnormal. 
Troubleshooting: 
 
3.4.15 ―EE‖ IDU or ODU Memory Chip Error 
Error display: IDU wired control,IDU and ODU receiver light board will display EE 
Error judgment condition and method: 
If ODU mainboard cannot read the memory chip, this error will be reported.   
Possible reason: 
■ Memory chip on the ODU mainboard is damaged. 
■. Memory chip is weakly welded.   
■. Memory chip lead is short-circuited.