No. Malfunction Name
Display Method of 
Indoor Unit
A/C status Possible Causes 
Dual-8 Code
Display
47
Malfunction of detecting 
plate(WIFI )
JF
Loads operate normally, while the unit can’t be 
normally controlled by APP.
1. Main board of indoor unit is damaged;
2. Detection board is damaged;
3. The connection between indoor unit and 
detection board is not good; 
48
Refrigerant recovery 
mode
Fo
Refrigerant recovery. The Serviceman operates 
it for maintenance.
49
Undened outdoor unit 
error
oE
Cool: compressor and outdoor fan stops 
operation, while indoor fan operates; Heat: 
compressor, outdoor fan and indoor fan stop 
operation. 
1. Outdoor ambient temperature exceeds the 
operation range of unit (eg: less than-20
o
C or 
more than 60
o
C for cooling; more than 30
o
C for 
heating); 
2. Failure startup of compressor?
3. Are wires of compressor not connected 
tightly?
4. Is compressor damaged?
5. Is main board damaged?