91
Installation and Maintenance
Service Manual
Procedure
Step
Loosen the connection clasps between
vertical louver and bottom case to 
remove vertion louver.
Screw off the screws that are locking the 
swing motor and take the motor off.
7.Remove vertical louver
8.Remove electric box assy
a
a
b
b
Loosen the connection clasps between
shield cover of electric box sub-assy and
electric box,and then remove the shield
cover of electric box sub-assy.
Remove the screw xing electric box 
assy.
Swing moto
temperature sensor
Main
board
Wiring
terminal
of motor
Wiring
terminal
of stepping
Cut  off  the  wire  binder and  pull  out  the
indoor tube temperature sensor.
Screw off one grounding screw.
Remove  the  wiring  terminals  of  motor  and
stepping motor.
Remove the electric box assy.
Screw  off  the  screws  that are  locking each
lead wire.
Screw
screw
①
Cut off the wire binder and pull out 
the indoor tube temperature sensor.
②
Screw off one grounding screw.
③
Remove the wiring terminals of motor 
and stepping motor.
④
Remove the electric box assy.
⑤
Screw off the screws thar are locking 
each lead wire.