120
Installation and Maintenance
Service Manual
Step Procedure
10. Remove 4-way valve assy
Unsolder the welding joints connecting the 4-way valve
assy, remove the 4-way valve.
Note:
Before unsoldering the welding joint, wrap the 4-way
valve with a wet cloth completely to avoid damage to
the valve caused by high temperature.
11. Remove electric expansion valve sub-Assy
Unsolder the spot weld of electric expansion valve sub-
Assy and condenser, and then remove the electric
expansion valve sub-Assy.
Note:
When unsoldering the spot weld, wrap the electric
expansion valve sub-Assy with wet cloth completely to
avoid damaging the valve due to high temperature.
12. Remove clapboard assy
Remove the screws xing the clapboard assy and then
remove the clapboard assy.
4-way valve assy
Electric expansion
valve sub-Assy
Electric expand
valve tting
Clapboard assy