47
Technical Information
Service Manual
NOTICE:
● It's low fan speed under dry mode.
● X-FAN function: Hold fan speed button for 2s in cool or dry
mode, the icon " " is displayed and the indoor fan will continue
operation for a few minutes in order to dry the indoor unit even
though you have turned off the unit. After energization, X-FAN
OFF is defaulted. X-FAN is not available in auto, fan or heat
mode.
● This function indicates that moisture on evaporator of indoor
unit will be blowed after the unit is stopped to avoid mould.
● Having set X-FAN function on: After turning off the unit by
pressing ON/OFF button indoor fan will continue running for a
few minutes. At low speed. In this period, hold fan speed button
for 2s to stop indoor fan directly.
● Having set X-FAN function off: After turning off the unit by
pressing ON/OFF button, the complete unit will be off directly.
3.
MODE
button
Press this button, auto, cool, dry, fan, heat mode can be selected
circularly. Auto mode is default while power on. Under heat
mode, the initial value is 28°C(82°F). Under other modes, the
initial value is 25°C(77°F).
HEAT
AUTO COOL DRY FAN
NOTICE:
● Only for cooling and heating unit. As for cooling only unit, it
won't have any action when it receives the signal of heating
operation.
4. button
Press " + " or " - " button once increase or decrease set
temperature 0.1°C(°F). Holding " + " or " - " button, set
temperature on remote controller will change quickly. On
releasing button after setting is nished, temperature indicator on
indoor unit will change accordingly.
When setting TIMER ON, TIMER OFF or CLOCK, press " + " or
" - " button to adjust time. (Refer to CLOCK, TIMER ON, TIMER
OFF buttons)
5.
TURBO
button
Press this button to activate / deactivate the Turbo function which
enables the unit to reach the preset temperature in the shortest
time. In cool mode, the unit will blow strong cooling air at super
high fan speed. In heat mode, the unit will blow strong heating air
at super high fan speed.
6. button
Press this button can select left & right swing angle. Fan blow
angle can be selected circularly as below:
no display
(stops at
current position)
NOTICE:
● Press this button continuously more than 2s, the main unit will
swing back and forth from left to right, and then loosen the button,
the unit will stop swinging and present position of guide louver
will be kept immediately.
● Under left and right swing mode, when the status is switched
from off to , if press this button again 2s later, status will
switch to off status directly; if press this button again within 2s,
the change of swing status will also depend on the circulation
sequence stated above.
7. button
Press this button can select up & down swing angle. Fan blow
angle can be selected circularly as below:
no display
(horizontal louvers
stops at current position)
● When selecting " ", air conditioner is blowing fan
automatically. Horizontal louver will automatically swing up &
down at maximum angle.
● When selecting " , , , , ", air conditioner is blowing fan
at xed position. Horizontal louver will stop at the xed position.
● When selecting " , , ", air conditioner is blowing fan at
xed angle. Horizontal louver will send air at the xed angle.
● Hold " " button above 2s to set your required swing angle.
When reaching your required angle, release the button.
NOTICE:
● " , , " may not be available. When air conditioner
receives this signal, the air conditioner will blow fan automatically.
Press this button continuously for more than 2s, the main unit
will swing back and forth from up to down, and then loosen the
button, the unit present position of guide louver will be kept
immediately.
● Under up and down swing mode, when the status is switched
from off to , if press this button again 2s later, status will
switch to off status directly; if press this button again within 2s,
the change of swing status will also depend on the circulation
sequence stated above.
8.
CLOCK
button
Press this button, the clock can be set up, signal blink and
display. Within 5 seconds, the value can be adjusted by pressing
+ or - button, if continuously press this button for 2 seconds
above, in every 0.5 seconds, the value on ten place of Minute
will be increased 1. During blinking, repress the clock button,
signal will be constantly displayed and it denotes the setting