112
6. Remove fan blade
Remove the bolt holding the blade then remove.
7. Remove electrical box assembly
Unplug the wire terminals of the compressor, motor, capaci-
tor and reactor. Remove the bonding and ground screws, then
remove screws holding box and remove box. Remove the screws
holding the re retardant box and remove,
8. Remove sound proof barrier
Carefully remove barrier
Disassembly of Outdoor Unit
18,000 btuh Warning - Wait 10 minutes aer power is disconnected before starting disassembly.
Fan Blade
Electrical Box
Fire retardant
electrical box
9. Remove isolation sheet
Remove screws holding sheet, then remove sheet
10. Remove refrigerant valves
Properly remove refrigerant. Protect valve assembly by wrapping
valves with wet cloth, unsolder valves, then remove screws hold-
ing support. Remove screws holding valves, then remove valves.
Barrier
Reactor
Isolation sheet
Capacitor
Valve